Heinrichs Weikamp OSTC (original, Mk2, 2N, 2C) and Frog

This document covers two older Heinrichs Weikamp protocols:

  • OSTC dump protocol (OSTC, OSTC Mk.2, OSTC 2N, OSTC 2C; PIC18 firmware). This is serial over USB only. One command byte returns a fixed-size memory image: a 6-byte preamble, a 256-byte block of internal EEPROM, battery and firmware bytes, then the complete external EEPROM profile ring (32 or 64 KiB). Dives are found in the ring by start and end markers. There is no per-dive request, no echo on the download command and no checksum.
  • Frog (serial over USB and Bluetooth classic). It uses an early variant of the hwOS command protocol in hw-ostc3.md, with a few deviations listed in Frog.

The dive record format (header versions 20, 21, 22, samples, divisors, events) is in hw-ostc-log-format.md.

Devices

VendorModelModel codeTransportsNotes
Heinrichs WeikampOSTC0USB serialserial number ≤ 300
Heinrichs WeikampOSTC Mk.21USB serialserial 301-2048
Heinrichs WeikampOSTC 2N2USB serialserial 2049-7000
Heinrichs WeikampOSTC 2C3USB serialserial > 7000
Heinrichs WeikampFrog0 (own family)USB serial, Bluetooth classicname prefix FROG

The dump protocol has no model query. The model codes above are derived from the serial number (dump offset 6, u16le) using the thresholds shown. They are a host-side convention, not a device value.

Identification:

  • USB: a USB-serial bridge enumerating as a virtual COM port. No vendor-specific VID:PID is documented. The later hwOS models use an FTDI FT232.
  • Frog Bluetooth classic: SPP, device name starting with FROG.

Confidence: likely (one open-source implementation for the model thresholds and the Frog name prefix). uncertain for the USB bridge chip on the PIC18 OSTCs.

Transport parameters

ParameterOSTC/Mk2/2N/2CFrog
Baud rate115200115200
Framing8N1, no flow control8N1, no flow control
Host read timeout4000 ms3000 ms
On openwait 100 ms, purge both directionswait 300 ms, purge

There is no wake-up sequence. The OSTC must be in surface mode (not diving, not asleep, not in a menu), where its UART receive interrupt is active.

Confidence: likely (one open-source implementation plus earlier observation notes that agree on 115200).

Session

OSTC / Mk2 / 2N / 2C

There is no handshake and no session state. Each command is one ASCII byte. The firmware handles the byte in its receive interrupt and performs the action at its next surface-loop pass. Some commands echo the byte, others do not.

Do not probe these devices with hwOS commands. The command letters overlap with the hwOS command set, but the meanings differ dangerously. For example, 63 enters simulator mode, 66 resets battery statistics and 69 writes EEPROM bank 1. A host that has to auto-detect SHOULD send BB first. hwOS and Frog devices answer BB 4D. The PIC18 OSTC ignores BB (it is not one of its command bytes).

Commands

OSTC / Mk2 / 2N / 2C

CommandH→DEchoArgumentsD→HSafe for a downloader
Dump61 (a)nonone33034 or 65802 bytes (below)yes: the download command
Set clock62 (b)yes6 bytes: hour, minute, second, month, day, year−2000nonemodifies the clock
Simulator mode63 (c)no: starts the dive simulator
Write EEPROM bank 064 (d)yes, and each data byte is echoed252 bytes (bank offsets 4-255)no
Firmware + MD2 hash65 (e)nonone18 bytes: firmware major, minor, 16-byte MD2 hashyes
Reset battery statistics66 (f)no
Read EEPROM bank 067 (g)nonone256 bytesyes
Reset deco data68 (h)yesnoneno: clears tissue saturation, CNS, no-fly time
Write EEPROM bank 169 (i)yesas 64no
Read EEPROM bank 16A (j)nonone256 bytesyes
Store tissue data6B (k)yesnonemodifies state
Screen dump6C (l)yesnonerun-length image (below)yes
Read EEPROM bank 26D (m)nonone256 bytesyes
Write EEPROM bank 26E (n)yesas 64no
BootloaderC1bootloader answers 57 4Bno: firmware update entry

The bootloader request C1 is answered by the bootloader with the PIC type byte 57 and 4B (K). It is tried at 19200 and at 115200 baud. Firmware is then written in 64-byte blocks. A downloader MUST NOT send C1.

Screen dump encoding (optional feature): 320 × 240 pixels, sent column by column (y runs fastest). Each run starts with a byte b:

  • b bit 7 = 0: black run of (b & 0x7F) + 1 pixels;
  • b bits 7-6 = 11: white run of (b & 0x3F) + 1 pixels;
  • b bits 7-6 = 10: two more bytes follow with an RGB565 colour (big-endian), and the run is (b & 0x3F) + 1 pixels.

Confidence: verified for the command letters, their actions, the dump layout up to the ring, the MD2 reply and the bank reads (vendor Mk2 firmware source). likely for echo behaviour of b/d/i/n/l, the 64 argument length, the screen encoding and the bootloader exchange (one open-source implementation).

Framing and integrity

There is no checksum. Checks available to the host:

  • dump bytes 0-5 MUST be AA AA AA AA AA 55;
  • the total length is fixed by the firmware version;
  • each dive record starts with FA FA and its profile ends with FD FD. The header has its own end marker FB FB (version 21: header bytes 55-56).

Worked example (dump prefix)

H→D  61
D→H  AA AA AA AA AA 55             preamble (offset 0-5)
     39 30 …                       EEPROM bank 0, 256 bytes (offset 6-261); serial = 0x3039 = 12345 → OSTC 2C
     E8 0F                         battery, u16le = 4072 (mV, likely)          (offset 262-263)
     02 5E                         firmware 2.94 (u16be 0x025E > 0x015A → 64 KiB ring)  (offset 264-265)
     <65536 bytes profile ring>    (offset 266-65801)

Memory layout

Dump layout (host buffer offsets):

OffsetSizeContent
06preamble AA AA AA AA AA 55
6256internal EEPROM bank 0. Offset 6-7 = serial number (u16le), offset 8-9 = total dive count
2622current battery voltage, low byte first
2642firmware major, minor. As u16be: version × 256 + minor
26632768 or 65536external EEPROM (profile ring), rotated (below)

Ring size: 32768 bytes when firmware (u16be at 264) ≤ 0x015A (1.90), otherwise 65536 bytes. The total dump is 33034 or 65802 bytes.

The device sends the ring starting at the byte after its current write position and wraps around. The oldest data therefore comes first and the newest dive ends near the end of the dump. The firmware writes FD FD FE at the end of the newest dive. The FE is overwritten by the next dive and lets the firmware find the newest dive after a reset. While a dive is in progress the firmware reserves 57 bytes for the header and writes the header only at the end of the dive. So an interrupted dive may have samples but no FA FA header.

Confidence: verified for the layout, preamble and rotation start (vendor firmware source). likely for the 1.90 size switch (one implementation plus observation notes: “firmware > 1.90”).

Download procedure

send 61
read 266 bytes; check preamble
size := 266 + (65536 if u16be(buf[264..266]) > 0x015A else 32768)
read the remaining bytes (large reads; the device streams without pauses)
end := size
cursor := size
loop:
    find the last occurrence of FA FA that starts at or after 266 and before cursor;
    if none: stop
    start := position of that FA FA
    search forward from start (not past end) for FD FD; if found:
        record := buf[start .. position of FD FD + 2]
        if record[3..8] == stored fingerprint: stop       (newest-first order)
        emit record
    end := start
    cursor := start

Records are therefore produced newest first. A record whose FD FD is not found before the start of the next-newer dive is skipped. This happens for the oldest, partly overwritten dive. A parser should also check that the version byte at record offset 2 is 20 or 21.

Fingerprint: 5 bytes at record offset 3 (month, day, year−2000, hour, minute of dive end).

Dive data format: see hw-ostc-log-format.md. The record starts with FA FA, so the header offsets in that document apply directly.

Date and time: local time of the dive end, no seconds, no time zone. See the log-format document for the start-time computation.

Confidence: likely (one open-source implementation, consistent with the vendor firmware’s record markers). An earlier observation scanned forward from offset 266 for FA FA 21 instead. It parses every dive and does no fingerprint filtering. Both approaches find the same records.

Frog

The Frog speaks the hwOS command protocol (hw-ostc3.md) at 115200 8N1, with these differences:

AspectFrog
BB (download mode)answered with 4D only: no echo
61 (full headers)no echo: the 65536 header bytes and then 4D follow directly
Other commandsechoed as in hwOS. Ready byte 4D
Service-mode entryAA AA AB AC. Answer 4B 4C, without echoing the key. Do not use
Compact headers 6Dnot supported. Always use 61
Identity 6917 bytes: u16le serial, firmware major, minor, 13 bytes custom text
Display text 6E15 bytes
Custom text 6313 bytes
Header layoutversion 22, see the log-format document
Profile locationring 000000-1FFFFF. Header offset 2 = begin pointer (u24le), offset 5 = end pointer
Fingerprintheader offset 9, 5 bytes
Dive counterheader offset 52, u16le
Firmware in headeroffset 32-33 (major, minor)

Profile length for 66: the device sends the 256-byte header followed by (ring distance from begin to end) − 6 bytes, where

distance = end − begin                   if end ≥ begin
         = end + 0x200000 − begin        otherwise
(begin == end means an empty profile)

Both pointers MUST lie in 000000-1FFFFF. Otherwise the header is corrupt. The newest dive is the non-empty slot with the highest dive counter. Download walks backwards from it, as for hwOS. The only validation applied to the received profile is the FD FD end marker. The Frog profile has no small header: the interval and divisors are in the dive header.

Firmware update commands and sizes differ from hwOS (116 KiB image). A downloader MUST NOT use them.

Confidence: likely (one open-source implementation. No vendor Frog documentation was available).

Model-specific variations

  • Firmware ≤ 1.90 on the PIC18 OSTCs: 32 KiB ring.
  • Profile version 20 (early firmware): 47-byte header, no mode byte, all gases enabled.
  • Version 21 adds average depth, total dive time, GF/multipliers, mode, last-stop setting, gas-enabled mask and on-time.

Open questions

  1. The serial-number thresholds for model detection are a host convention. The vendor does not document them, and they may misclassify refurbished or re-serialised units.
  2. The USB bridge chip of the PIC18 OSTCs (FTDI or other) is unconfirmed.
  3. The Frog header layout and the “distance − 6” profile length have no vendor source.
  4. Whether the Frog Bluetooth module supports anything beyond SPP (for example BLE) is unknown. Implementations list Bluetooth classic only.
  5. The meaning of internal EEPROM bank 0 beyond the serial number and dive count is not documented here. The hwOS bank-0 map does not apply to the PIC18 OSTC.

References