Heinrichs Weikamp hwOS family (OSTC 2/3/Plus/Sport/cR/Nano/2 TR, OSTC 4/5)

All Heinrichs Weikamp computers from the OSTC 3 onwards share one byte-oriented command protocol. The 8-bit computers run hwOS (Tech or Sport): OSTC 3, OSTC Plus, OSTC 2 (2015 and later), OSTC 2 TR, OSTC Sport, OSTC cR and OSTC Nano. The OSTC 4 and OSTC 5 run separate 32-bit firmware that implements the same download commands. The protocol runs unchanged over USB serial (FTDI), Bluetooth classic (SPP) and Bluetooth Low Energy (a serial-port emulation profile). The host sends a single command byte. The device echoes it, exchanges a fixed or self-describing amount of data, and ends with a ready byte. The device keeps a table of 256 dive headers of 256 bytes each (plus a 16-byte compact form) and a profile ring. The host reads the header table, picks the dives to fetch, and requests each dive by its slot number. The dive data format is described in hw-ostc-log-format.md. The Frog uses a variant of this command set and is covered in hw-ostc-legacy.md.

Devices

The device reports a one-byte hardware descriptor (command 6A, or byte 1 of the command 60 reply) and a model byte (byte 4 of the 60 reply). The hardware descriptor is a bit set, so several products share values. The vendor advises that a host distinguish only hwOS Sport, hwOS Tech and OSTC 4/5, because all units of one kind parse identically.

VendorModelHardware descriptorModel byte (60)TransportsNotes
Heinrichs WeikampOSTC cR05 or 0700USB, BT, BLEhwOS Tech
Heinrichs WeikampOSTC 30A00USBhwOS Tech
Heinrichs WeikampOSTC 2 (2015+)11, 13 or 1B00BT, BLEhwOS Tech
Heinrichs WeikampOSTC Sport12 or 1300 (one revision of the vendor doc lists 51)BT, BLEhwOS Sport, feature low byte 02
Heinrichs WeikampOSTC Plus (OSTC 3+)1A or 1300BT, BLEhwOS Tech
Heinrichs WeikampOSTC 2 TR3300BT, BLEhwOS Tech, tank receiver
Heinrichs WeikampOSTC Nanounknown00USB, BLEhwOS; see open questions
Heinrichs WeikampOSTC 43B43BT, BLE32-bit firmware
Heinrichs WeikampOSTC 53B44BT, BLE32-bit firmware

Meaning of the hardware descriptor bits (vendor doc):

BitMeaning
0rechargeable battery with battery-management chip
1ambient light sensor
2analog sensor inputs and S8 digital input
3digital optical input
4BLE module
5hwOS: tank pressure receiver. OSTC 4/5 documentation: 32-bit dual core
6, 7unused, 0

The value 3B (bits 0, 1, 3, 4, 5) identifies the OSTC 4/5 generation. A host MUST know which generation it talks to, because the firmware version encoding, the header slot order and several log-format details differ (see Model-specific variations).

Identification per transport:

  • USB: FTDI FT232 USB-serial bridge (standard FTDI driver). The vendor documents no custom VID:PID.
  • Bluetooth classic and BLE advertised names start with OSTC. Observed names include OSTC2, OSTC #…, OSTC+…, OSTC3#…, OSTCs… (Sport) and OSTC4…. A module that has not been named yet may advertise the Telit/Stollmann module default BM+SR….
  • BLE: the service UUID identifies the radio module (see below).

Confidence: verified for hardware descriptors, bit meanings, the model bytes 43/44 and the Sport feature byte (vendor interface documents and OSTC 4 firmware source). likely for advertised-name prefixes. uncertain for the OSTC Nano descriptor.

Transport parameters

Serial (USB and Bluetooth classic)

  • 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.
  • Bluetooth classic exposes a standard SPP (RFCOMM) serial port. On the OSTC Sport the module may request legacy PIN pairing with PIN 0000.
  • Vendor timing: inside a command, each further byte must arrive within 400 ms of the previous one (the timeout restarts on every byte). The idle timeout between commands is 120 s. After it the device leaves COM mode by itself and sends FF. Before the first byte, the device waits up to 4 min for BB or AA. The vendor recommends that hosts flush after every command or parameter block and wait for the device reply before sending more.
  • Host read timeout used by existing implementations: 2000 to 3000 ms per read, after a 300 ms settle delay and an input purge on open.
  • Writes: existing implementations send up to 1024 bytes per write call, or 64 bytes per call for the OSTC 4/5.

Bluetooth Low Energy

Two radio modules are in use. Both carry the raw serial byte stream, with no extra framing.

Telit (Stollmann) BlueMod, “Terminal I/O” profile (OSTC Sport, 2, Plus, 2 TR, cR, early OSTC 4):

RoleUUIDProperties
Service0000FEFB-0000-1000-8000-00805F9B34FB (16-bit FEFB)
UART data RX (host writes data)00000001-0000-1000-8000-008025000000write without response, 1-20 bytes
UART data TX (device sends data)00000002-0000-1000-8000-008025000000notify, 1-20 bytes
UART credits RX (host grants credits)00000003-0000-1000-8000-008025000000write (with response), u8
UART credits TX (device grants credits)00000004-0000-1000-8000-008025000000indicate, u8

The Terminal I/O connection setup is mandatory and ordered:

  1. Enable indications on credits TX (00000004…) by writing 02 00 to its CCCD, and wait for the write response. If the module requires a secure link, bonding is triggered here.
  2. Enable notifications on data TX (00000002…) by writing 01 00 to its CCCD.
  3. Write an initial credit count (u8, 0-255) to credits RX (00000003…) and wait for the write response. The link is then established.

Flow control is per packet. One credit allows one notification or one write of 1 to 20 bytes. The device may send as many data notifications as the host has granted. The host has to replenish credits before they run out. One existing implementation grants 254 (FE), counts received notifications, and grants another 222 when only 32 remain. The host may only write data while it holds credits that the device granted through credits-TX indications. It subtracts one per written packet.

The Terminal I/O module advertises manufacturer-specific data: length 08, then FF 8F 00 09 B0, then compatibility version 01, operation mode (00 bonding only, 01 functional, 10 bondable and functional) and a “connection requested” flag.

u-blox “u-connectXpress” BLE Serial Port Service (newer OSTC units, including later OSTC 4/5):

RoleUUID
Service2456E1B9-26E2-8F83-E744-F34F01E9D701
FIFO (data, both directions: write and notify)2456E1B9-26E2-8F83-E744-F34F01E9D703
Credits (both directions: write and indicate/notify)2456E1B9-26E2-8F83-E744-F34F01E9D704

The same credit scheme is applied: subscribe to the credits characteristic first, then to the FIFO, then write an initial credit grant.

Packet sizes: host writes are at most 20 bytes per packet. No MTU exchange is required. Notifications carry at most 20 bytes of payload under the default MTU.

A variant without credits was observed: one implementation subscribes only to data TX and never grants credits. Whether this works depends on the module configuration (open question).

Confidence: verified for the Terminal I/O UUIDs, properties and setup order (Telit/Stollmann Terminal I/O Profile Client Implementation Guide, distributed by Heinrichs Weikamp) and for the use of Terminal I/O and u-blox SPS (vendor interface document 2025). likely for the u-blox UUIDs and the credit-refill strategy (one open-source implementation). likely for serial line parameters other than the vendor-stated 115200 8N1.

Session

Ready byte, echo and unsupported commands

  • In download mode the ready byte is 4D (M). In service mode it is 4C (L).
  • The device echoes every command byte it understands. It then performs the command and finally sends the ready byte. FF (exit) gets the echo but no ready byte.
  • A device that does not implement a command answers with the ready byte only (no echo). A host SHOULD treat “ready byte received where the echo was expected” as “command unsupported”. On the OSTC 4/5 the unknown-command path sends the ready byte, which confirms this.
  • After any command except exit, the host MUST read the trailing ready byte before it sends the next command.

Entering download mode

H→D  BB
D→H  BB 4D

The device shows “Download mode enabled”.

Entering service mode (do not use for downloading)

Service mode enables flash and firmware commands. A downloader has no reason to enter it, because every download command also works in download mode.

H→D  AA            (then wait)
D→H  4B
H→D  AB  D→H AB    (wait for each echo before sending the next key byte)
H→D  CD  D→H CD
H→D  EF  D→H EF
D→H  4C

On a wrong key the device returns to waiting for BB/AA. The OSTC 4/5 reads all three key bytes and then answers 4B AB CD EF 4C in one burst.

Identification

  1. 60: hardware and feature descriptor (5 bytes). If unsupported (old firmware), fall back to 6A (1 byte). Some early firmware supports neither.
  2. 69: identity (64 bytes): serial number and firmware version.

Shutdown

H→D  FF
D→H  FF

The device shows “Exited” for 2 s and powers down the radio. The host should exit before the 120 s idle timeout fires. On the OSTC 4/5 in service mode, any command byte below 60 also ends the session (this guards against modem strings such as RING).

Confidence: verified (vendor COMM-mode documentation, vendor interface PDF, OSTC 4 firmware source).

Commands

Download-mode commands (all also accepted in service mode):

CommandH→DArguments (after echo)D→H after echoNotes
Start / download modeBBnone4D
Hardware + features60none5 bytes, then 4Du16be hardware (00 hh), u16be feature, u8 model
Full headers61none65536 bytes (256 × 256), then 4Dslot 0 first
Set clock626 bytes: hour, minute, second, month, day, year−20004Dvalues are range-checked. Modifies the device
Custom text6360 bytes, NUL-terminated4Dmodifies the device
Get dive661 byte slot number 0-255256-byte header + profile, then 4Dsee Download procedure
Identity69none64 bytes, then 4Du16le serial, 2 bytes firmware, 60 bytes custom text
Hardware descriptor6Anone1 byte, then 4D
Firmware details6B1 byte: FF main, FE RTE, 10 font pack4 bytes, then 4DOSTC 4/5 only. Unknown id → FF FF FF FF
BT signal strength6Cnone4DOSTC 4/5 only, shows on device
Compact headers6Dnone4096 bytes (256 × 16), then 4DhwOS 1.92+ and OSTC 4/5. Recommended for BLE
Display text6E16 bytes4Dshown on screen (15 characters on hwOS, 4 × 12 on OSTC 4/5)
Set icon6Fvariable data4DOSTC 4/5 only. Modifies the device: do not send
Read setting limits701 byte id4 or 7 bytes, then 4DOSTC 4/5 only
Read setting721 byte id1-4 bytes (OSTC 4/5: always 4), then 4D
Write setting771 byte id, then 1-5 bytes (OSTC 4/5: always 5)4Dmodifies the device
Reset all settings78none4Ddestructive: factory defaults
ExitFFnonenone

Setting ids for 72/77 include gases 1-5 (10-14: O2 %, He %, type, change depth), diluents 1-5 (15-19) and setpoints 1-5 (1A-1E: cbar, change depth). Single-byte options start at 1F. A downloader does not need them. On hwOS, the host must pause after the id byte of 77, because the device only knows how many value bytes follow after it has evaluated the id. Existing implementations wait 10 ms.

Commands a downloader MUST NOT send. They are listed only so that an implementation can reject them:

ByteModeEffect
20serviceread raw flash range (3-byte address, 3-byte length, big-endian). Read-only, but needs service mode
22serviceerase the complete logbook
23servicereset battery gauge
30, 31servicewrite flash (stream; 256-byte page)
40, 42serviceerase one / N 4 KiB flash blocks, no confirmation
50servicestart firmware update (followed by a 5-byte checksum, then reboot)
73, 74, 75, 76service (OSTC 4/5)upload firmware blob (hwOS 4: CPU2 / main firmware / RTE / fonts)
71, 79, 80-82service (OSTC 4/5)manufacturing data, second serial, Bluetooth name
83-89service (OSTC 4/5)copy, overwrite or repair logbook and sample memory
FEservice (OSTC 4/5)hardware unit tests
C1servicejump to the low-level bootloader (cold start)
6F, 62, 63, 77, 78downloadmodify settings, clock, text or icon. Only send on explicit user request

Confidence: verified (vendor interface PDFs 2019 and 2025, COMM-mode documentation 2020, OSTC 4 firmware source).

Framing and integrity

There is no framing, escaping, compression, encryption or checksum on the download path. Integrity rests on:

  • the command echo and the trailing ready byte,
  • exact response lengths (fixed per command, or computed from the header for 66),
  • the header start and end markers FA FA … FB FB (bytes 0-1 and 254-255 of every 256-byte header),
  • the profile end marker FD FD,
  • the profile length repeated in the profile’s own first three bytes.

Over BLE the byte stream is split into notifications of up to 20 bytes. Their boundaries carry no meaning.

Worked example: identity and one empty dive

H→D  BB
D→H  BB 4D
H→D  69
D→H  69 39 30 03 5E <60 bytes custom text> 4D
     → serial = 0x3039 = 12345, firmware (hwOS) = 3.94
H→D  66
D→H  66
H→D  07                           (slot 7)
D→H  FA FA 00 00 00 00 00 00 24 08 00 00 … (256-byte header) … FB FB
     08 00 00 FD FD               (empty profile: length 8, then end marker)
     4D

Here the header announces a profile length of 8 at bytes 9-11, and 8 − 3 = 5 profile bytes follow. This is the form hwOS sends when the profile of a dive has been overwritten or is invalid. The begin and end pointers (bytes 2-7) are zero.

Confidence: verified for markers and the empty-profile form (vendor COMM documentation). likely for the length arithmetic (see below).

Memory layout

  • External flash: 4 MiB (000000-3FFFFF) on hwOS devices. The profile ring occupies 000000-1FFFFF (2 MiB) and wraps. The firmware staging area starts at 3E0000. Raw flash access exists only in service mode and is not needed for downloading. The OSTC 4/5 has no raw-read command.
  • Logbook: 256 header slots of 256 bytes each. A slot that has never been used reads as all FF. When the ring is full, the oldest profiles are overwritten (“first in, first out”). Their headers may survive and are then served with an empty profile.
  • Slot order: the order of the 256 slots is not chronological. Sort by the date/time in the header, or by the internal dive counter (header offset 80, compact offset 13). On the OSTC 4/5, slot i as sent corresponds to internal entry 255 − i, counted backwards from the newest dive. So the newest dive is the highest-numbered non-empty slot. The same slot number is used for 66.

Confidence: verified for the 256 × 256 table, FF fill and OSTC 4 slot mapping (vendor doc and OSTC 4 source). likely for the flash map (2 MiB ring, 4 MiB size, firmware area: one open-source implementation plus a vendor source comment).

Download procedure

open transport; settle 300 ms; purge input
send BB, expect BB 4D
send 60 → if echo: read 5 bytes + 4D
          else (got 4D only): send 6A → if echo: read 1 byte + 4D, else no descriptor
send 69, read 64 bytes + 4D
generation := OSTC4/5 if hardware descriptor == 3B else hwOS
send 6D; if unsupported: send 61 (full headers) instead
for each slot: skip if all bytes are FF; read profile length L, fingerprint, dive counter
determine newest slot:
    hwOS:     slot with the highest dive counter
    OSTC 4/5: last non-empty slot in index order
walk slots from newest backwards (wrapping modulo 256):
    skip empty slots
    stop if the 5-byte fingerprint equals the stored fingerprint
    expected := 256 + L − 3
    (full-header fallback only: if header firmware < 0.93, expected := expected − 3)
    send 66, expect echo, send slot number
    read 256-byte header
    if (hwOS) header bytes 2..7 are all 0 and header L == 8:
         expected := 256 + 5          (profile was invalidated)
    read expected − 256 profile bytes, then 4D
    validate (below), store
send FF, read echo

Validation of a received dive, as done by existing implementations:

  1. The version byte (header offset 8) and the date, time, max depth and dive time (offsets 12-21) must equal those of the logbook entry. With compact headers, also the dive counter (offset 80 against compact offset 13). With full headers, the whole of bytes 12-255 must match.
  2. If the profile does not end with FD FD, or is shorter than 2 bytes, keep only the header (no samples).
  3. A profile that is exactly FD FD is a valid empty profile.
  4. Otherwise the profile’s first three bytes (u24le length) must equal the header length field at 9-11. On the OSTC 4/5 the header field is 3 larger than the profile field. Mismatch → keep the header only.

Fingerprint: the 5 bytes at header offset 12 (year−2000, month, day, hour, minute). In the compact header they are at offset 3.

Progress estimate: the vendor states roughly 3 bytes of profile per second of dive time (about 21.6 KB for one hour).

Confidence: likely (one open-source implementation, consistent with vendor documentation). The “L − 3” rule and the firmware-0.93 correction are not in vendor documentation: see open questions.

Dive data format

See hw-ostc-log-format.md: 256-byte header versions 23 and 24, the 16-byte compact header, the profile “small header” with divisor table, and the sample and event encoding.

Date and time

Local time without time zone. Year is 2000-based. With profile version 24 (all OSTC 4/5 dives and newer hwOS dives) the stored timestamp is the start of the dive. With 23 it is the end. Set clock order: hour, minute, second, month, day, year−2000.

Model-specific variations

AspecthwOS (8-bit)OSTC 4/5
Firmware in 69 reply, bytes 2-3major, minor (u16be, e.g. 03 5E = 3.94)u16le packed: bits 15-11 major, 10-6 minor, 5-1 patch, bit 0 beta
Firmware in dive header, offset 48-49major, minorsame packed u16le
Header slot orderstorage orderreversed (slot i = internal entry 255 − i)
Header length field vs profile length fieldequalheader = profile + 3
60 model byte0043 (OSTC 4), 44 (OSTC 5)
Write chunk sizeup to 102464 bytes recommended
77 write length1-5 value bytes depending on idalways 5
72 read length1-4 bytes depending on idalways 4
Raw flash commands 20/30/31/40/42yes (service)no
Profile when samples are missingheader with zero pointers, length 8, 08 00 00 FD FDfirmware synthesises dummy samples from header data

Example of OSTC 4 firmware packing: version 1.7.5 (not beta) = (1<<11)|(7<<6)|(5<<1)|0 = 0x09CA, sent as CA 09.

When the OSTC 4/5 is in its bootloader (service mode), sending 60 has been reported to drop the Bluetooth link. One implementation therefore sends 6A first in service mode, and if that returns 3B it assumes model 43 without sending 60.

The OSTC 4/5 internally stores logbook version 30. Over the wire it sends 24 for entries of that version. For entries of any other internal version it sends FF, with offsets 57-58 set to FF FF and offset 244 set to FF.

hwOS Tech firmware since 3.09 and hwOS Sport since 10.64 support the 256-byte flash write 31. This matters only for firmware update.

Confidence: verified for the firmware encoding, slot order, length offset, dummy samples and model bytes (OSTC 4 firmware source and vendor doc). likely for the bootloader 60 behaviour (one implementation only).

Open questions

  1. Exact meaning of the header profile-length field. The vendor says it counts the profile “including final FD FD” (and once names offsets 8-10 instead of 9-11). Implementations transfer L − 3 bytes after the header, and on hwOS the profile’s own length field equals L. Why the length counts 3 bytes more than are sent is unexplained.
  2. The firmware-older-than-0.93 correction (another −3) comes from one implementation and has no vendor source.
  3. OSTC Nano hardware descriptor value is not documented.
  4. Hardware descriptor 13 is listed for OSTC 2, Plus and Sport. Only the feature byte (Sport 02) separates Sport from Tech.
  5. The 2019 vendor document lists model byte 51 for the OSTC Sport. The 2020 COMM documentation says hwOS always sends 00.
  6. The 2025 vendor table says 60 returns “Data (6)”, but the byte-by-byte description and the firmware source give 5 data bytes.
  7. Whether BLE downloads work without the Terminal I/O credit handshake. One implementation omits it, while the module vendor declares it mandatory.
  8. u-blox SPS characteristic properties are taken from an open-source implementation. The u-blox document UBX-16011192 was not consulted.

References

  • Heinrichs Weikamp, External Interface for Heinrichs Weikamp Dive-Computers with hwOS (OSTC3, OSTC cR, OSTC 2 and OSTC Plus), last update 2019-04-10, distributed with the hwOS sources (doc/hwos_interface.pdf), https://code.heinrichsweikamp.com/public/hwos_code.
  • Heinrichs Weikamp, External Interface … hwOS and OSTC4/5 (hwos4_interface_v16.pdf), last update 2025-07-13, in the OSTC 4 sources, https://code.heinrichsweikamp.com/public/ostc4.
  • Heinrichs Weikamp, OSTC hwos3 COMM Mode Documentation (comm-docu.txt), 2020-03-16, in the hwOS sources.
  • Heinrichs Weikamp OSTC 4/5 firmware source (GPL), tComm.c, logbook.c, logbook.h, settings.c, used as a factual reference only.
  • Stollmann (Telit), Terminal I/O Profile – Client Implementation Guide, release r02, https://www.heinrichsweikamp.net/downloads/TIO_Implementation_Guide_r02.pdf.
  • u-blox, u-connectXpress Bluetooth Low Energy Serial Port Service, UBX-16011192 (cited by the vendor, not consulted).
  • libdivecomputer (LGPL-2.1), used as a factual reference; no code copied.
  • Subsurface (GPL-2.0) BLE transport, used as a factual reference for the u-blox UUIDs and credit handling; no code copied.