Shearwater dive log format

This document describes the dive records downloaded by the procedure in shearwater.md. There are two encodings:

  • Block format (“Predator-like”): a 128-byte opening block, fixed-size samples, a 128-byte closing block, and (usually) a 128-byte final block. The Predator always uses this format. Petrel-family computers return it when dives are read through base address 0xC0000000.
  • Native format (PNF, “Petrel Native Format”): a sequence of 32-byte records, each tagged by its first byte. Petrel-family computers return it through base 0x80000000. Shearwater’s desktop software also stores logs in this format.

All multi-byte integers are big-endian unless stated otherwise. Offsets are zero-based.

Telling the formats apart

TestResult
Data came from the Predator full dumpblock format, 16-byte samples
Petrel family, first two bytes are FF FFblock format, 32-byte samples
Petrel family, first two bytes are anything elsenative format (first byte is a record type, normally 10)

Confidence: likely.

Units

The units byte (opening offset 8, both formats) selects the units for depths and temperatures:

ValueDepthTemperature
0metres°C
1feet (× 0.3048 → m)°F ((F − 32) × 5/9 → °C)

Tank pressures are always in units of 2 psi (× 2 × 0.0689475729 → bar), whatever the units setting. Atmospheric pressure is always in mbar, density in kg/m³.

Block format

A dive is opening block | samples… | closing block | final block.

  • Opening block: 128 bytes, starts FF FF.
  • Samples: 16 bytes each on the Predator, 32 bytes on Petrel-family computers. A sample that is all zero bytes is padding and is skipped.
  • Closing block: 128 bytes, starts FF FE.
  • Final block: 128 bytes, starts FF FD. Petrel-family downloads always include it. On Predator data it is present when the last block starts FF FD. Downloaders append the Predator’s identity block as this final block.

The sample interval is fixed at 10 s.

Opening block (128 bytes)

OffsetTypeRaw unitMeaning
0x00u16be—FFFF marker
0x02u16be—dive number (internal counter)
0x04u8%gradient factor low
0x05u8%gradient factor high
0x06u16bemin (uncertain)surface interval before the dive
0x08u8—units, see Units
0x09u80.1 Vbattery voltage (uncertain)
0x0Cu32besdive start, seconds since 1970-01-01 on the local wall clock (fingerprint)
0x11u80.01 barlow setpoint (Predator)
0x12u80.01 barhigh setpoint (Predator)
0x13bcd8—firmware version (uncertain)
0x14–0x1D10 × u8%O₂ of gases 1–10. Gases 1–5 are open circuit, 6–10 diluents
0x1E–0x2710 × u8%He of gases 1–10
0x2Fu16bembarsurface (atmospheric) pressure
0x43u8—decompression model, see Decompression model
0x44u8—VPM-B conservatism
0x53u16bekg/m³water density (1000 = fresh)
0x55u8%VPM-B/GFS gradient factor
0x56u8bit maskO₂ sensors calibrated (bit 0 = cell 1)
0x57, 0x59, 0x5B3 × u16be1/100000 bar/mVcalibration of cells 1–3
0x70u8—dive mode (log version ≥ 8), see Dive mode
0x78u8—battery type (log version ≥ 7), see Battery type
0x7Fu8—log version

In the block format, every gas is treated as enabled, and air integration is read from the samples whenever the log version is ≥ 7.

Closing block (128 bytes)

OffsetTypeRaw unitMeaning
0x00u16be—FFFE marker
0x02u16be—dive number, equal to the opening block’s
0x04u16bem or ft, whole unitsmaximum depth
0x06u16bemindive time

Final block (128 bytes)

OffsetTypeMeaning
0x00u16beFFFD marker
0x02u32beserial number
0x0Abcd8firmware version
0x0Du8model code (see shearwater.md)

Confidence: likely for fields with no remark. Fields marked uncertain come from one source and have no corroboration.

Native format (PNF)

A dive is a sequence of 32-byte records. Byte 0 is the record type. An all-zero record is padding. Record order is: opening records, then samples interleaved with events and other records, then closing records, then the final record.

Record types

TypeRecordDecoded below
00padding (whole record zero)—
01dive sampleDive sample
02freedive samples (4 per record)Freedive record
03Avelo sampleDive sample
10–19opening records 0–9Opening and closing records
20–29closing records 0–9same
30info eventInfo event
40DiveCAN eventlayout unknown
50button presslayout unknown
60surface ppO₂layout unknown
70–75tissue-loading snapshotTissue snapshot
80–87opening-record validity mapslayout unknown
88dive-sample validity maplayout unknown
E1extended dive sampleExtended sample
FFfinal recordFinal record

Records 0–4 (opening and closing) are always present. A log without them is invalid. Records 5 and up depend on the log version and the model. Petrel and Petrel 2 on native-format firmware (from about v71) may omit record 5.

Decoders SHOULD keep unknown records verbatim.

Confidence: types 01–03, 10–29, 30, E1 and FF likely (two independent sources). The names of 40–88 are uncertain (one source, which in turn cites the vendor’s desktop parser).

Opening and closing records

Offsets include the type byte at 0. Fields not listed are unknown.

Opening 0 (10)

OffsetTypeRaw unitMeaning
1u8—FF on observed logs (remnant of the block-format marker)
2u16be—dive number
4u8%gradient factor low
5u8%gradient factor high
6u16bemin (uncertain)surface interval
8u8—units
9u80.1 Vbattery voltage (uncertain)
12u32besdive start, local wall clock, seconds since 1970 (fingerprint)
20–2910 × u8%O₂ of gases 1–10 (1–5 open circuit, 6–10 diluent)
30–312 × u8%He of gases 1–2

Opening 1 (11)

OffsetTypeRaw unitMeaning
1–88 × u8%He of gases 3–10
16u16bembarsurface (atmospheric) pressure

Opening 2 (12)

OffsetTypeMeaning
18u8decompression model
19u8VPM-B conservatism

Opening 3 (13)

OffsetTypeRaw unitMeaning
3u16bekg/m³water density
5u8%VPM-B/GFS gradient factor
6u8bit maskO₂ cells calibrated (bit 0 = cell 1)
7, 9, 113 × u16be1/100000 bar/mVcalibration of cells 1–3

Opening 4 (14)

OffsetTypeVersionMeaning
1u8≥ 8dive mode
9u8≥ 7battery type
16u8alllog version
17u16beallgas enabled mask, bit i = gas i+1
28u8≥ 7air-integration mode, see Air integration
29u8≥ 7gas-time-remaining transmitter mask, bit i = transmitter i+1. Two or more bits set means sidemount

Opening 5 (15), log version ≥ 9

OffsetTypeRaw unitMeaning
13 × bcd8—transmitter 1 serial (6 decimal digits)
6u16beuncertaintransmitter 1 rated pressure
8u16beuncertaintransmitter 1 reserve pressure
103 × bcd8—transmitter 2 serial
15u16beuncertaintransmitter 2 rated pressure
17u16beuncertaintransmitter 2 reserve pressure
23u16bemssample interval (default 10000 if the record is absent)
26i32beminUTC offset
30u8hdaylight-saving offset

Opening 6 (16)

OffsetTypeVersionMeaning
1u16be≥ 11configured scrubber (stack) time, s. 0 = feature off
3u16be≥ 11remaining stack time at dive start, s
5u8≥ 12recreational OC sub-mode (only when dive mode = 6): 0 three-gas nitrox, 1 air, 2 nitrox, 3 OC recreational
19u8≥ 13transmitter 1 enabled
202 × ASCII≥ 13transmitter 1 name (first character O = oxygen, D = diluent on CCR)
22u8≥ 13transmitter 2 enabled
232 × ASCII≥ 13transmitter 2 name
253 × bcd8≥ 13transmitter 3 serial
28u16be≥ 13transmitter 3 rated pressure
30u16be≥ 13transmitter 3 reserve pressure

Opening 7 (17), log version ≥ 13

OffsetTypeMeaning
1u8transmitter 3 enabled
22 × ASCIItransmitter 3 name
43 × bcd8transmitter 4 serial
7u16betransmitter 4 rated pressure
9u16betransmitter 4 reserve pressure
11u8transmitter 4 enabled
122 × ASCIItransmitter 4 name

Opening 8 (18): layout unknown.

Opening 9 (19) and closing 9 (29), log version ≥ 17: surface position at dive start and end.

OffsetTypeRaw unitMeaning
16u8—fix status: 0 no satellites, 1 no fix, 2 2D fix, 3 3D fix, 10 disabled, FF unknown
21i32be1e-5 degreelatitude
25i32be1e-5 degreelongitude

Only use the position when the status is 2 or 3.

Closing 0 (20)

OffsetTypeRaw unitMeaning
1u8—FE on observed logs
2u16be—dive number
4u16be0.1 m or 0.1 ftmaximum depth (note: tenths, unlike the block format)
6u24besdive time
9u80.1 Vbattery voltage at end (uncertain)
12u32besend time, local wall clock (uncertain)

Another implementation reads the dive time as a u16be at offset 7. That is the same value whenever the dive is shorter than 65536 s.

Closing 6 (26), log version ≥ 11: offset 3, u16be, remaining stack time at dive end, in seconds.

Closing records 1–5, 7 and 8 mirror the opening records with end-of-dive values. Their layouts have not been confirmed.

Final record (FF)

OffsetTypeMeaning
1u8FD
2u32beserial number
10bcd8firmware version
13u8model code. Prefer this over a model code supplied by the caller

Native logs read through base 0x80000000 end with this record. Logs from the early native format (base 0x90000000) lack it. The vendor’s desktop software treats the final record plus the three records after it (all zero) as one 128-byte unit.

Confidence: likely, except for fields marked uncertain.

Dive sample

Both formats use the same sample layout. The table gives offsets relative to the start of the sample fields:

  • block format: sample start;
  • native format: record start + 1 (after the type byte).

The Predator’s 16-byte sample has only offsets 0–15. Petrel-family samples have 0–30 (block format: 32 bytes, last byte unknown; native: 31 bytes after the type byte).

OffTypeRaw unitMeaning
0u16be0.1 m / 0.1 ftdepth
2u16bem / ftnext stop depth. 0 = no decompression obligation
4u16bemintime to surface
6u80.01 barppO₂ (voted / average)
7u8%current gas O₂
8u8%current gas He
9u8minstop time when off 2 ≠ 0, else no-decompression limit
10u8%battery remaining (uncertain)
11u8bitsstatus, see below
12u8mVO₂ cell 1
13i8°C / °Fwater temperature (see below)
14u8mVO₂ cell 2
15u8mVO₂ cell 3
16u16be0.01 Vbattery voltage (uncertain)
18u80.01 barcurrent setpoint (Petrel family)
19u16besee Air integrationtransmitter 2 pressure (log version ≥ 7)
21u8mingas time remaining (log version ≥ 7). F0–FF are codes: FF not paired, FE no communication, FD not available in this mode, FC not available during deco, FB tank size or rated pressure not set
22u8%CNS (Petrel family)
23u8mceiling. Under DCIEM: safe-ascent depth, whole metres (uncertain)
24u8%GF99, FF = not applicable. Under DCIEM: safe-ascent depth, hundredths (uncertain)
25u16bemintime to surface if the diver stayed 5 more minutes, FFFF = n/a (uncertain)
27u16besee Air integrationtransmitter 1 pressure (log version ≥ 7)
29u16be0.01 (unit unknown)surface air consumption, FFFF = n/a (uncertain)

Status byte (offset 11):

BitMaskMeaning
001gas switch suggested
102ppO₂ comes from an external source. Skip the ppO₂ values when set
204high setpoint selected (Predator: choose opening 0x12 over 0x11)
308semi-closed circuit (when bit 4 is clear)
410open circuit. Clear = closed-circuit loop
520bail-out from CCR. ppO₂ values are not meaningful
6–7C0number of O₂ solenoid firings in this interval (uncertain)

Bits 3 and 5 have different names in different sources (“SC” vs “circuit switch type”, “bail-out” vs “CCR mode”). Bits 1, 2 and 4 agree across sources.

Temperature. A signed byte. Non-negative values are used as-is. Negative raw values r are corrected to min(r + 102, 0). That maps raw −128…−103 to −26…−1 and raw −102…−1 to 0. Convert from °F when the units byte is 1. The correction only reproduces what one reference does. It has not been checked on sub-zero dives.

ppO₂ and cells (closed circuit only, i.e. status bit 4 clear):

  • Voted ppO₂ = offset 6 / 100 bar.
  • Cell n ppO₂ = raw mV × calibrationn / 100000 bar. Report a cell only if its bit is set in the calibration mask.
  • Predator only: multiply the calibration by 2.2.
  • If every masked cell has the factory default calibration 2100, the cells were probably not calibrated. This happens with DiveCAN controllers, which keep calibration in the sensor module. Either drop the cell values, or estimate one common factor: average voted ppO₂ divided by the average of the cells computed with 2100. Apply it only if it falls outside 0.98–1.02.

No-decompression limit. Offset 9 is 0 with no stop (offset 2 = 0) on the first sample before the computer has a value; read it as absent there and as 0 min elsewhere (likely).

Setpoint. Petrel family: offset 18 / 100 bar. Predator: opening 0x11 (low) or 0x12 (high), chosen by status bit 2.

Gas. O₂ and He at offsets 7–8 give the current mix. A sample with both zero carries no gas information. A change of (O₂, He, closed-circuit flag) from the previous sample is a gas switch. In closed-circuit mode the mix is a diluent. The first sample’s mix is the starting gas, not a switch.

Time. Samples carry no timestamp. Sample k (counting from 1) is at k × interval. The interval is 10 s, or opening 5 offset 23 (ms) when log version ≥ 9. Another implementation puts the first sample at 0 instead. See Open questions.

Avelo sample (03): same layout as 01. The status byte is not used and the sample is treated as open circuit. Only transmitter 1 (offset 27) is read.

Confidence: offsets 0–9, 11–15, 18, 19, 21, 22 and 27 likely (two independent sources). Offsets marked uncertain come from one source.

Air integration

The air-integration mode (opening 4 offset 28) decides which tank each pressure field belongs to:

ModeMeaning
0off
1transmitter 1 only
2transmitter 2 only
3transmitters 1 and 2
4high-pressure CCR: the two sample pressures are diluent (offset 27) and O₂ (offset 19)
5on (log version ≥ 13, tanks enabled individually in opening 6/7)
6on, with GNSS (uncertain)

Each pressure field is a u16be:

  • FFF0–FFFF are status codes: FFFF AI off, FFFE no communication for over 90 s, FFFD no communication for over 30 s, FFFC transmitter not paired.
  • Otherwise bits 0–11 are pressure in units of 2 psi, and bits 12–15 are the transmitter battery state: 0 normal, 1 critical, 2 warning. A pressure of 0 means no reading.

The first and last non-zero readings give the begin and end pressure of a tank.

Teric: the 6-digit transmitter serial is stored with its three BCD bytes in reverse order. Decode as BCD, then swap the first and last digit pairs.

Extended sample (E1)

Follows a dive sample and adds tanks for the same instant. Offsets include the type byte.

OffsetTypeVersionMeaning
1u16be≥ 13transmitter 3 pressure (same encoding as above)
3u16be≥ 13transmitter 4 pressure
5u16be≥ 14HP-CCR diluent pressure, 2 psi units, no status codes
7u16be≥ 14HP-CCR O₂ pressure, 2 psi units, no status codes

Freedive record (02)

The record holds four 8-byte freedive samples at record offsets 0, 8, 16 and 24. Byte 0 of the first sample is the record type. Unused trailing samples are all zero and end the record. Any freedive record sets the dive mode to freedive.

Offset in sub-sampleTypeRaw unitMeaning
1u16bembarabsolute pressure
3i16be0.1 °Ctemperature (always Celsius)
0, 5–7——unknown

Depth in metres = (pressure − atmospheric) × 100 / (density × 9.80665). Atmospheric pressure comes from opening 1 offset 16 (mbar), density from opening 3 offset 3. Each sub-sample advances time by one sample interval.

Confidence: likely (one reference, internally consistent).

Info event (30)

OffsetTypeMeaning
1u8event code
4u32betimestamp, same clock as the dive start
8u32beparameter 1
12u32beparameter 2

Known codes:

CodeMeaningParameter 1Parameter 2
38 (26)diver tag/bookmarkcompass heading in degrees, FFFFFFFF = nonetag value

Confidence: likely.

Tissue snapshot (70–75)

Six consecutive records, 70 to 75, make one snapshot. Bytes 1–3 of each record are zero. Bytes 4–31 hold little-endian IEEE-754 f32 values, seven per record. Record 75 holds six values and then a big-endian u32 timestamp at bytes 28–31. Values 0–15 are N₂ loading of compartments 1–16 in bar. Values 16–31 are He loading of compartments 1–16 in bar. Values 32–39 are unidentified, and value 40 has always been zero. The first snapshot comes before the first sample and is stamped with the dive start time. Later ones follow about every 4 minutes.

Confidence: uncertain (one source, Perdix 2 and Petrel 3 only).

Header-level fields

Dive mode

Taken from opening 4 offset 1 (native) or offset 0x70 (block) when the log version is ≥ 8. For older logs, derive it from the samples: any closed-circuit sample (status bit 4 clear) means CC, or SC if bit 3 is set. Any freedive record means freedive. Otherwise the dive is OC.

ValueModeCommon model
0closed circuit / bail-outCCR
1open circuit, technicalOC
2gaugegauge
3ppO₂ displaygauge
4semi-closed / bail-outSCR
5closed circuit, second variantCCR
6open circuit, recreational (sub-mode in opening 6)OC
7freedivefreedive
12AveloOC

Gas list

There are ten fixed slots. Slots 1–5 are open-circuit gases and 6–10 diluents. A slot is reported if its O₂ and He are not both zero and it is either enabled (gas mask bit, native format; always in the block format) or used in a sample. Diluents are reported only in CC/SC dives. Freedives have no gases. Mixes first seen in samples that match no slot are added (up to 20 mixes in total).

Decompression model

ValueModelParameters
0Bühlmann with gradient factorsGF low/high at opening offsets 4/5
1VPM-Bconservatism (opening 2 offset 19 / block 0x44)
2VPM-B/GFSconservatism as above, GFS gradient factor (opening 3 offset 5 / block 0x55)
3DCIEM—

Battery type

ValueBattery
11.5 V alkaline
21.5 V lithium
31.2 V NiMH
43.6 V Saft
53.7 V Li-ion

Confidence: uncertain (one source).

Salinity and atmospheric pressure

Density 1000 kg/m³ means fresh water. Any other value means salt water, with that density. The atmospheric pressure is in mbar.

Date and time

The dive start (opening offset 12) is seconds since 1970-01-01T00:00 counted on the diver’s local wall clock. Decode it as if it were UTC to get the local date and time.

On the Teric, with log version ≥ 9 and opening 5 present, the UTC offset is offset_minutes × 60 + dst_hours × 3600 seconds, from opening 5 offsets 26 and 30. Other models have left these bytes zero on observed logs, which should be read as “no time zone”.

Log versions

Log versions below 6 are not reliably recorded. Treat them as 6.

VersionAdded
6baseline
7air integration: sample pressures, gas time remaining, AI mode, GTR mask; battery type
8dive mode in the header
9opening 5: transmitter serials and pressures, sample interval, UTC offset and DST
11scrubber stack time (opening 6, closing 6)
12recreational OC sub-mode
13transmitters 3 and 4 (opening 6/7, extended sample E1); per-tank enable and name; sidemount GTR mask
14HP-CCR diluent and O₂ pressures in E1
17GNSS position (opening 9, closing 9)

The dive-sample layout is the same in versions 7 through 17.

Example (native format, real Perdix 2, imperial, fresh water at altitude)

Excerpts from a published capture. Only the leading bytes of each record are shown.

opening 0  10 FF 00 02 28 55 0B 88 01 0F 00 00 6A 47 A0 8D 00 46 82 A2 15 ...
           dive 2, GF 40/85, units 1 (imperial), start 0x6A47A08D, gas 1 O2 21 %
opening 1  11 00 … (offset 16) 03 31      atmospheric 817 mbar
opening 3  13 0B 03 03 E8                 density 1000 (fresh)
opening 4  14 06 … (offset 16) 11 00 01   mode 6 (OC rec), log version 17, gas mask 0001
opening 5  15 … (offset 23) 27 10         interval 10000 ms
sample     01 00 37 00 00 00 01 14 15 00 00 58 12 00 41
           depth 5.5 ft, TTS 1 min, ppO2 0.20, O2 21 %, He 0, status 12 (OC + external), 65 °F
closing 0  20 FE 00 02 00 42 00 00 1C 0F 00 00 6A 47 A0 A4
           dive 2, max 6.6 ft, dive time 28 s

In this capture opening 0 offset 19 is A2, which is not valid BCD. That casts doubt on reading a firmware version from that offset.

Open questions

  1. Is the first sample at time 0 or at one interval? Implementations differ.
  2. Status bits 3 and 5: which name is correct (“semi-closed” or “circuit switch type”; “bail-out” or “CCR mode”)?
  3. Units of the transmitter rated and reserve pressures (opening 5–7), and of the SAC field at sample offset 29.
  4. Meaning of opening offset 6 (surface interval?), offset 9 (battery voltage?) and offset 19 (firmware?). Meaning of closing 0 offset 12: it looks like an end time, but the capture shows 23 s after the start for a 28 s dive.
  5. The temperature correction for negative raw values has not been checked on sub-zero dives.
  6. Layouts of opening/closing 8, of records 40, 50, 60 and 80–88, and of the unknown bytes in freedive sub-samples.
  7. Is AI mode 6 “on with GNSS” or something else?
  8. One reading treats native record type 01 as “first sample” and 02 as “further samples”. The other sources treat 02 as a freedive record. Freedive data supports the latter. Logs mixing 01 and 02 in an OC dive would settle it.
  9. Air-integration mode 4 (HP-CCR) puts diluent and O₂ pressures in the dive sample (offsets 27 and 19). Log version 14 adds them to the extended sample E1 (offsets 5 and 7) as well. Are these the same readings, and does mode 4 still use the dive-sample fields from version 14 on? The divecomputer-rs parser reads both into the same two tanks and lets E1 override the dive sample at the same instant (uncertain).
  10. Are transmitters 3 and 4 in E1 used only under AI mode 5, or under other modes too? The parser reads them only under mode 5 (and 6) with the tank enabled in opening 6/7 (uncertain).
  11. The ceiling at sample offset 23 is documented in whole metres. Is it in feet when the units byte is 1? Until that is known, the parser does not decode the ceiling.
  12. A block-format log without a final block is read as a Predator log (16-byte samples, cell calibration × 2.2, setpoints from the opening block), because Petrel-family block logs always include one. A Petrel-family block log that lost its final block would be misread (likely).
  13. What does a sample interval of 0 in opening 5 mean? The parser rejects such a log instead of guessing.
  14. Can an info event (30) carry a timestamp before the dive start? Such an event has no place on the elapsed-time axis; the parser drops it.

References