Pelagic VT Pro protocol (Oceanic, Aeris, Sherwood)

The VT Pro protocol is used by early Pelagic air-integrated computers: Oceanic VT Pro, Versa Pro and Pro Plus 2; Aeris Atmos 2, Atmos AI, Elite and 500 AI; Sherwood Wisdom. They connect through a serial interface cable at 9600 baud. The cable contains a microcontroller that must be initialised before the dive computer answers. The host reads memory in 16-byte pages, up to four pages per command. Each page carries its own 8-bit checksum. Short control replies use a nibble-sum checksum. Memory layout and download algorithm follow pelagic-common.md. The Aeris 500 AI uses a variant with a different cable mode and a dedicated logbook command.

Devices

VendorModelModel codeTransportNotes
Aeris500 AI4151serial“INTR” cable mode, layout L-500AI, no version string
OceanicVersa Pro4155seriallayout L-32A
AerisAtmos 24158seriallayout L-32A
OceanicPro Plus 24159seriallayout L-32A
AerisAtmos AI4244seriallayout L-32A
OceanicVT Pro4245seriallayout L-32A
SherwoodWisdom4246seriallayout L-32W
AerisElite424Fseriallayout L-32A

Identification: by the 16-byte version string; see the model table. The Aeris 500 AI returns no version string, so the host must be told the model in advance.

Confidence: likely.

Transport parameters

ParameterValue
Baud rate9600
Framing8N1, no flow control
Read timeout3000 ms (9000 ms for the calibration command)
DTRhigh for the whole session
RTSpulsed low to reset the cable, see below

See ../transports/serial.md for serial details.

Confidence: likely.

Session

  1. Open the port at 9600 8N1. Set DTR high.

  2. Set RTS low, wait 100 ms, set RTS high. This resets the cable’s microcontroller.

  3. Wait 100 ms (1000 ms for the 500 AI). Discard all buffered data.

  4. Cable init. Send the cable-mode command. The cable answers with a 13-byte ASCII string, with no ACK byte before it:

    ModeModelsH→DD→H
    MODall except 500 AIAA 00MOD--OK_V2.00 = 4D 4F 44 2D 2D 4F 4B 5F 56 32 2E 30 30
    INTR500 AI20 00INTR-OK_V1.11 = 49 4E 54 52 2D 4F 4B 5F 56 31 2E 31 31
  5. Download mode. Send 88 00. The reply is 5A, 8 bytes, and a nibble-sum checksum. The 8 bytes are the first half of the version string and can be ignored. The device must be in PC mode (selected by the user on the device).

  6. Version string (MOD mode only). Send 72 03 00 00, then 72 03 10 00. Each reply is 5A, 8 bytes, a nibble-sum checksum, and the end byte 51. The two 8-byte halves form the 16-byte version string. In INTR mode the version string is treated as 16 zero bytes.

  7. Calibration (recommended). Send 18 00 with the read timeout raised to 9 s. The device needs about 6 s. The reply is 5A and two bytes; the second byte must be 00. Afterwards, memory reads are considerably faster.

  8. Select the layout by matching the version string (L-32A if nothing matches). For the 500 AI, use layout L-500AI.

  9. Download (see below).

  10. Quit. Send 6A 05 A5 00. The reply is 5A 51. The device returns to surface mode.

Variant: another implementation expects a 5A before the 13-byte cable reply. It does not send the calibration command or the quit command.

Confidence: likely for the order and bytes; uncertain whether a 5A precedes the cable init reply.

Commands

CommandH→D bytesD→H responseNotes
Cable init (MOD)AA 0013 ASCII bytesno ACK
Cable init (INTR)20 0013 ASCII bytes500 AI
Download mode / ident88 005A + 8 bytes + nibble-sum
Version half72 03 XX 00, XX = 00 or 105A + 8 bytes + nibble-sum + 51MOD only
Calibrate18 005A + 2 bytes (second = 00)~6 s
Read pages34 FH FL LH LL 005A + n × (16 bytes + sum8)F = first page, L = last page, u16be page numbers (address / 16), n = L − F + 1 ≤ 4
Read logbook index52 BB EE 005A + k × (8 bytes + nibble-sum)500 AI only. BB = first entry index, EE = last entry index, k = EE − BB + 1
Keep-alive6A 08 00 005A 51
Quit6A 05 A5 005A 51

Error handling: if the first reply byte is not 5A (for example A5 = NAK), or no reply comes within the timeout, resend the command. One implementation allows 2 resends.

Confidence: likely.

Framing and integrity

Commands are raw bytes with no framing. Replies:

  • 5A (ACK) first, then the payload.
  • Page data: each 16-byte page is followed by its sum8 (8-bit sum of the 16 bytes).
  • 8-byte control replies: followed by a nibble-sum byte. This is the 8-bit sum of the high and low nibbles of every byte: cs = Σ ((b >> 4) + (b & 0x0F)) mod 256.
  • Version-half replies end with the byte 51 after the checksum.

Worked example, first version half of a VT Pro:

H→D  72 03 00 00
D→H  5A 56 54 50 52 4F 20 20 72 40 51

56 54 50 52 4F 20 20 72 = “VTPRO r”. Nibble sum: 5+6+5+4+5+0+5+2+4+F+2+0+2+0+7+2 = 0x40.

Second half (firmware bytes 31 30):

H→D  72 03 10 00
D→H  5A 31 30 20 20 32 35 36 4B 30 51

Worked example, reading two pages at 0x0240 (pages 0x24 and 0x25):

H→D  34 00 24 00 25 00
D→H  5A <16 bytes page 0x24> <sum8> <16 bytes page 0x25> <sum8>

A page of 12 34 56 78 9A BC DE F0 12 34 56 78 9A BC DE F0 has sum8 70.

Confidence: likely.

Memory layout

Layouts L-32A (VT Pro, Versa Pro, Pro Plus 2, Atmos 2, Atmos AI, Elite), L-32W (Wisdom) and L-500AI. See pelagic-common.md.

Aeris 500 AI

  • Memory size 0x20000. Device-info page at 0x0000, serial encoding S2.

  • The pointer page is at 0x0110:

    OffsetTypeMeaning
    0x02u8Index of the first logbook entry
    0x03u8Index of the last logbook entry (inclusive)
    0x04u16leProfile ring first page (× 16 = address)
    0x06u16leProfile ring last page (× 16 = address)
  • Logbook entries are not read from memory. The host requests them with the index command 52.

  • Profile ring 0x0200..0x20000. Logbook entries use pointer form E1.

Confidence: likely (one source).

Download procedure

For all models except the 500 AI, follow the common procedure, reading with command 34 and up to 4 pages per command.

For the 500 AI:

  1. Read the pointer page at 0x0110 (command 34, one page).
  2. Send 52 <first> <last> 00. After the 5A, read (last − first + 1) entries of 8 bytes, each followed by a nibble-sum byte. Verify each checksum.
  3. Skip all-FF entries. If an entry equals the stored fingerprint, discard everything collected so far, because the device returns entries oldest first.
  4. Continue with the profile passes of the common procedure, using the collected entries.

Confidence: likely.

Dive data format

A dive record is the 8-byte logbook entry followed by the profile bytes. The minimum record size is 56 bytes. Layout:

0x00..0x07   logbook entry
0x08..0x27   profile header (32 bytes)
0x28..       8-byte samples
last 16      footer
FieldLocationType, unitConversion
Start tank pressureu16le at 0x26, masked 0x0FFF2 psi× 2 psi. If start and end are both 0, there is no tank
Sample interval (all except 500 AI)(b0x27 >> 4) & 0x07index0..3 → 2, 15, 30, 60 s; other values → depth-based sampling (see below)
Sample interval (500 AI)b0x27 >> 4index3..9 → 2, 5, 10, 15, 20, 25, 30 s; other values → depth-based
Max depth (all except 500 AI)u16le at footer +0, masked 0x01FFft× 0.3048 m
Max depth (500 AI)b(footer + 1)ft
O2 (all except 500 AI)b(footer + 3)%0 → 21 %
O2 (500 AI)(u16le at footer +2 & 0x0FF0) >> 4%0 → 21 %
End tank pressureu16le at footer +5, masked 0x0FFF2 psi× 2 psi

There is one gas mix and at most one tank. The dive time is derived from the samples.

Samples

8-byte samples from offset 0x28 to the footer. Skip samples that are all 00 or all FF.

FieldAll except 500 AI500 AI
Time stamphours = bcd(s1 & 0x0F), minutes = bcd(s0)same
Depths3, ft(u16le@2 & 0x0FF0) >> 4, ft
Temperatures6, °F(u16le@6 & 0x0FF0) >> 4, °F
Deco stops5 >> 4, units of 10 ft; 0 = no stop-
Deco / NDL timeu16le@4 & 0x0FFF, minutes (NDL when no stop)-

Sample timing: the time stamp has a resolution of one minute, and several samples share it. Let m be the time stamp in minutes, and i the 0-based position of the sample among those with the same stamp.

  • Time-based interval t: at most 60 / t samples share a stamp. Sample time = m × 60 + (i + 1) × t seconds. Ignore extra samples. If the stamp jumps by more than one minute, or goes backwards, treat it as a data error.
  • Depth-based sampling: count the n non-empty samples with the same stamp. Sample time = m × 60 + round((i + 1) × 60 / n) seconds.

Date and time

From the logbook entry (all models except 500 AI):

FieldSource
Minutebcd(b0)
Hourbcd(b1 & 0x7F), 12-hour; PM = b1 bit 7
Daybcd(b3 & 0x7F)
Monthb4 >> 4
Yearif the record has at least 40 bytes: 2000 + bcd(((b0x23 & 0xC0) >> 2) + (b0x22 >> 4)); else 2000 + bcd(b4 & 0x0F)

The logbook entry stores only the last year digit; the full year is in the profile header.

500 AI:

FieldSource
Minutebcd(b0)
Hourbcd(b1 & 0x0F) + 10 × (b3 & 0x01), 12-hour; PM = b3 bit 3
Day(b2 >> 4) | ((b3 & 0x02) << 3)
Monthb3 >> 4
Year1999 + (b2 & 0x0F)

Hours are converted with hour mod 12, plus 12 if PM. No seconds, no time zone.

Confidence: likely (one implementation).

Model-specific variations

  • Wisdom: layout L-32W, otherwise identical.
  • 500 AI: INTR cable mode, no version string, index-based logbook, own pointer page and dive-format fields as listed.

Open questions

  • Whether a 5A precedes the 13-byte cable init reply (the sources disagree).
  • The contents of the 8-byte reply to 88 00, and of the calibration reply’s first byte.
  • Whether the 500 AI’s year base (1999) is correct for all firmware versions.
  • Meaning of the 500 AI device-info and header bytes not listed.

References