Pelagic Veo 250 protocol (Oceanic, Genesis, Aeris, Sherwood, Hollis, Seemann)

The Veo 250 protocol is used by a group of mid-2000s Pelagic computers without air integration: Oceanic Veo 180, Veo 200 and Veo 250; Genesis React Pro; Aeris XR-2; Sherwood Insight; Hollis DG02; Seemann XP5. They connect through a serial interface cable at 9600 baud. The cable contains a microcontroller that must be initialised first. The host reads memory in 16-byte pages, up to four per command. Each page is followed by an 8-bit checksum, and every reply ends with a trailer byte. Memory layout and download algorithm follow pelagic-common.md. The dive record format described here is also used by the Genesis React Pro White, which itself downloads with the atom2 protocol.

Devices

VendorModelModel codeTransportNotes
GenesisReact Pro4247serial
OceanicVeo 200424Bserial
OceanicVeo 250424Cserial
SeemannXP54251serialversion string starts SEEMANN R
OceanicVeo 1804252serial
AerisXR-24255serial
SherwoodInsight425Aserial
HollisDG024352serial
GenesisReact Pro White4354serialatom2 protocol, this dive format

All use layout L-32V. Identification is by version string; see the model table.

Confidence: likely.

Transport parameters

ParameterValue
Baud rate9600
Framing8N1, no flow control
Read timeout3000 ms
DTRhigh for the whole session
RTSpulsed low to reset the cable

See ../transports/serial.md.

Confidence: likely.

Session

  1. Open the port at 9600 8N1. Set DTR high.
  2. Set RTS low, wait 100 ms, set RTS high, wait 100 ms. Discard buffered data.
  3. Cable init. Send 55 00. The cable answers with 13 ASCII bytes PPS--OK_V2.00 (50 50 53 2D 2D 4F 4B 5F 56 32 2E 30 30). If no byte arrives at all, continue anyway. A different non-empty answer is an error.
  4. Wait 100 ms.
  5. Version. Send 90 00. This also switches the device into download mode; the device must be in PC mode, which the user selects on the device. The reply is 5A, 16 version bytes, a sum8 of those 16 bytes, and the trailer A5.
  6. Match the version string (see pelagic-common.md).
  7. Download (see below).
  8. Quit. Send 98 00. No reply is expected.

Variant: another implementation expects 5A followed by 13 bytes for the cable init. It does not check them or send the quit command.

Confidence: likely.

Commands

CommandH→D bytesD→H responseNotes
Cable init55 0013 ASCII bytes, or nothingno ACK
Version90 005A + 16 bytes + sum8 + A5
Read pages20 FL FH LL LH 005A + n × (16 bytes + sum8) + A5F = first page, L = last page, both little-endian page numbers (address / 16), n = L − F + 1 ≤ 4
Keep-alive91 LL LH 005A A5 A5L = last page number read (little-endian)
Quit98 00none

Before every command, the host discards pending input. If the first reply byte is not 5A, or nothing arrives, wait 100 ms and resend (one implementation allows 2 resends). The last byte of every reply with data MUST be A5.

Note that the page numbers here are little-endian, whereas the VT Pro protocol uses big-endian.

Confidence: likely.

Framing and integrity

Commands are raw bytes. Replies are 5A, the payload, and the trailer A5. Each 16-byte block of the payload (version string or memory page) is followed by its sum8.

Worked example (Veo 250, firmware bytes 31 30):

H→D  90 00
D→H  5A 56 45 4F 20 32 35 30 20 52 31 30 20 32 35 36 4B 7C A5

The string is “VEO 250 R10 256K”. sum8 of the 16 bytes = 0x7C.

Worked example, reading the pointer page (address 0x0040 = page 4):

H→D  20 04 00 04 00 00
D→H  5A <16 bytes> <sum8> A5

Confidence: likely.

Memory layout

Layout L-32V (see pelagic-common.md): memory 0x8000, device-info page 0x0000 (serial encoding S1), pointer page 0x0040 (logbook pointer mode G1), logbook ring 0x0400..0x0600 with 8-byte entries, profile ring 0x0600..0x8000, profile pointer form E1.

Confidence: likely.

Download procedure

Follow the common procedure, reading up to 4 pages per command.

Confidence: likely.

Dive data format

A dive record is the 8-byte logbook entry followed by the profile. Its minimum size is 56 bytes.

0x00..0x07   logbook entry
0x08..0x27   profile header
0x28..       8-byte samples
last 16      footer
FieldLocationType, unitConversion
Sample intervalb0x27 & 0x03index0..3 → 2, 15, 30, 60 s. React Pro and React Pro White: use index (i + 1) mod 4 instead
Dive timeb(footer + 3), b(footer + 4)minutes, hoursseconds = 60 × b(footer+3) + 3600 × b(footer+4)
O2b(footer + 6)%0 → 21 %

There is one gas mix and no tank pressure. Max depth is taken from the samples.

Samples

8-byte samples from 0x28 to the footer. Skip all-00 samples. Each sample is one interval after the previous one.

FieldReact Pro, React Pro White, InsightAll others
Depths2, fts2, ft
Temperatures6, °Fs7, °F
Deco stops7 >> 4, units of 10 ft (0 = none)s5 >> 4, units of 10 ft
Deco / NDL time((s3 & 0xC0) << 2) | s4, minutesu16le@4 & 0x0FFF, minutes

When the stop value is 0, the time is the no-decompression limit.

Date and time

From the logbook entry:

FieldSource
Minuteb2 (binary)
Hourb3 (binary, 0..23)
Dayb1 & 0x1F
Monthb7 >> 4
Year2000 + (b5 >> 4) + ((b1 & 0xE0) >> 1), then +3 for Veo 200 and Veo 250, +2 for React Pro

No seconds, no time zone.

Worked example (Veo 250): logbook bytes xx 0C 1E 0E xx 90 xx 60.

  • day = 0x0C & 0x1F = 12
  • minute = 0x1E = 30, hour = 0x0E = 14
  • month = 0x60 >> 4 = 6
  • year = 2000 + (0x90 >> 4) + ((0x0C & 0xE0) >> 1) + 3 = 2000 + 9 + 0 + 3 = 2012

Result: 2012-06-12 14:30.

Confidence: likely for fields; uncertain for the year composition (see open questions).

Model-specific variations

  • React Pro and React Pro White: shifted interval index, different temperature and deco bytes.
  • Insight: same sample bytes as the React Pro, normal interval index.
  • React Pro White downloads with the atom2 protocol (layout L-64R).

Open questions

  • The year formula combines a 4-bit field with a 3-bit field weighted by 16, and adds per-model offsets. Real dumps are needed to confirm it.
  • Whether a 5A precedes the cable init reply (the sources disagree).
  • Meaning of the other logbook, header and footer bytes (for example tank or gas settings, max depth).