Pelagic Veo 250 protocol (Oceanic, Genesis, Aeris, Sherwood, Hollis, Seemann)
The Veo 250 protocol is used by a group of mid-2000s Pelagic computers without air integration: Oceanic Veo 180, Veo 200 and Veo 250; Genesis React Pro; Aeris XR-2; Sherwood Insight; Hollis DG02; Seemann XP5. They connect through a serial interface cable at 9600 baud. The cable contains a microcontroller that must be initialised first. The host reads memory in 16-byte pages, up to four per command. Each page is followed by an 8-bit checksum, and every reply ends with a trailer byte. Memory layout and download algorithm follow pelagic-common.md. The dive record format described here is also used by the Genesis React Pro White, which itself downloads with the atom2 protocol.
Devices
| Vendor | Model | Model code | Transport | Notes |
|---|---|---|---|---|
| Genesis | React Pro | 4247 | serial | |
| Oceanic | Veo 200 | 424B | serial | |
| Oceanic | Veo 250 | 424C | serial | |
| Seemann | XP5 | 4251 | serial | version string starts SEEMANN R |
| Oceanic | Veo 180 | 4252 | serial | |
| Aeris | XR-2 | 4255 | serial | |
| Sherwood | Insight | 425A | serial | |
| Hollis | DG02 | 4352 | serial | |
| Genesis | React Pro White | 4354 | serial | atom2 protocol, this dive format |
All use layout L-32V. Identification is by version string; see the model table.
Confidence: likely.
Transport parameters
| Parameter | Value |
|---|---|
| Baud rate | 9600 |
| Framing | 8N1, no flow control |
| Read timeout | 3000 ms |
| DTR | high for the whole session |
| RTS | pulsed low to reset the cable |
Confidence: likely.
Session
- Open the port at 9600 8N1. Set DTR high.
- Set RTS low, wait 100 ms, set RTS high, wait 100 ms. Discard buffered data.
- Cable init. Send
55 00. The cable answers with 13 ASCII bytesPPS--OK_V2.00(50 50 53 2D 2D 4F 4B 5F 56 32 2E 30 30). If no byte arrives at all, continue anyway. A different non-empty answer is an error. - Wait 100 ms.
- Version. Send
90 00. This also switches the device into download mode; the device must be in PC mode, which the user selects on the device. The reply is5A, 16 version bytes, a sum8 of those 16 bytes, and the trailerA5. - Match the version string (see pelagic-common.md).
- Download (see below).
- Quit. Send
98 00. No reply is expected.
Variant: another implementation expects 5A followed by 13 bytes for the cable init. It does not
check them or send the quit command.
Confidence: likely.
Commands
| Command | H→D bytes | D→H response | Notes |
|---|---|---|---|
| Cable init | 55 00 | 13 ASCII bytes, or nothing | no ACK |
| Version | 90 00 | 5A + 16 bytes + sum8 + A5 | |
| Read pages | 20 FL FH LL LH 00 | 5A + n × (16 bytes + sum8) + A5 | F = first page, L = last page, both little-endian page numbers (address / 16), n = L − F + 1 ≤ 4 |
| Keep-alive | 91 LL LH 00 | 5A A5 A5 | L = last page number read (little-endian) |
| Quit | 98 00 | none |
Before every command, the host discards pending input. If the first reply byte is not 5A, or
nothing arrives, wait 100 ms and resend (one implementation allows 2 resends). The last byte of
every reply with data MUST be A5.
Note that the page numbers here are little-endian, whereas the VT Pro protocol uses big-endian.
Confidence: likely.
Framing and integrity
Commands are raw bytes. Replies are 5A, the payload, and the trailer A5. Each 16-byte block of
the payload (version string or memory page) is followed by its sum8.
Worked example (Veo 250, firmware bytes 31 30):
H→D 90 00
D→H 5A 56 45 4F 20 32 35 30 20 52 31 30 20 32 35 36 4B 7C A5
The string is “VEO 250 R10 256K”. sum8 of the 16 bytes = 0x7C.
Worked example, reading the pointer page (address 0x0040 = page 4):
H→D 20 04 00 04 00 00
D→H 5A <16 bytes> <sum8> A5
Confidence: likely.
Memory layout
Layout L-32V (see pelagic-common.md): memory 0x8000, device-info page 0x0000 (serial encoding S1), pointer page 0x0040 (logbook pointer mode G1), logbook ring 0x0400..0x0600 with 8-byte entries, profile ring 0x0600..0x8000, profile pointer form E1.
Confidence: likely.
Download procedure
Follow the common procedure, reading up to 4 pages per command.
Confidence: likely.
Dive data format
A dive record is the 8-byte logbook entry followed by the profile. Its minimum size is 56 bytes.
0x00..0x07 logbook entry
0x08..0x27 profile header
0x28.. 8-byte samples
last 16 footer
Header
| Field | Location | Type, unit | Conversion |
|---|---|---|---|
| Sample interval | b0x27 & 0x03 | index | 0..3 → 2, 15, 30, 60 s. React Pro and React Pro White: use index (i + 1) mod 4 instead |
| Dive time | b(footer + 3), b(footer + 4) | minutes, hours | seconds = 60 × b(footer+3) + 3600 × b(footer+4) |
| O2 | b(footer + 6) | % | 0 → 21 % |
There is one gas mix and no tank pressure. Max depth is taken from the samples.
Samples
8-byte samples from 0x28 to the footer. Skip all-00 samples. Each sample is one interval after
the previous one.
| Field | React Pro, React Pro White, Insight | All others |
|---|---|---|
| Depth | s2, ft | s2, ft |
| Temperature | s6, °F | s7, °F |
| Deco stop | s7 >> 4, units of 10 ft (0 = none) | s5 >> 4, units of 10 ft |
| Deco / NDL time | ((s3 & 0xC0) << 2) | s4, minutes | u16le@4 & 0x0FFF, minutes |
When the stop value is 0, the time is the no-decompression limit.
Date and time
From the logbook entry:
| Field | Source |
|---|---|
| Minute | b2 (binary) |
| Hour | b3 (binary, 0..23) |
| Day | b1 & 0x1F |
| Month | b7 >> 4 |
| Year | 2000 + (b5 >> 4) + ((b1 & 0xE0) >> 1), then +3 for Veo 200 and Veo 250, +2 for React Pro |
No seconds, no time zone.
Worked example (Veo 250): logbook bytes xx 0C 1E 0E xx 90 xx 60.
- day = 0x0C & 0x1F = 12
- minute = 0x1E = 30, hour = 0x0E = 14
- month = 0x60 >> 4 = 6
- year = 2000 + (0x90 >> 4) + ((0x0C & 0xE0) >> 1) + 3 = 2000 + 9 + 0 + 3 = 2012
Result: 2012-06-12 14:30.
Confidence: likely for fields; uncertain for the year composition (see open questions).
Model-specific variations
- React Pro and React Pro White: shifted interval index, different temperature and deco bytes.
- Insight: same sample bytes as the React Pro, normal interval index.
- React Pro White downloads with the atom2 protocol (layout L-64R).
Open questions
- The year formula combines a 4-bit field with a 3-bit field weighted by 16, and adds per-model offsets. Real dumps are needed to confirm it.
- Whether a
5Aprecedes the cable init reply (the sources disagree). - Meaning of the other logbook, header and footer bytes (for example tank or gas settings, max depth).
References
- libdivecomputer (LGPL-2.1), https://github.com/libdivecomputer/libdivecomputer, used as a factual reference; no code copied.