The oldest Suunto dive computers that can be downloaded: the Solution (circa 1990s, air only) and the Eon generation (Eon, Solution Alpha, Solution Nitrox / Vario). Both are read over a wired serial interface at 1200 baud and return their whole memory in one transfer. There are no addressed reads: the host pulls the complete memory image and then carves dives out of a profile ring buffer inside it.

The two families use different wake-up sequences and memory sizes, but share the same idea of a delta-encoded depth profile in feet terminated by marker bytes. The Eon-style dive record is also reused by the Suunto Spyder (see suunto-vyper.md).

Devices

VendorModelModel codeTransportsNotes
SuuntoSolutionnone reportedserial256-byte memory, handshake per byte
SuuntoEonnone reportedserial2304-byte memory, single bulk reply
SuuntoSolution Alphanone reportedserialsame protocol as Eon
SuuntoSolution Nitrox (also sold as Vario)none reportedserialEon protocol; nitrox flag in dive header

None of these devices report a model code; the host must know which family it is talking to.

Identification: the devices are attached through Suunto’s serial interface cable (RS-232 or a USB-serial adapter). No USB IDs, Bluetooth names or IrDA nicknames apply. Generic serial handling is described in ../transports/.

Confidence: likely (single reference implementation).

Transport parameters

ParameterValue
Baud rate1200
Framing8 data bits, no parity, 2 stop bits (8N2)
Flow controlnone
RTScleared (de-asserted) when the port is opened
DTRSolution: asserted before the transfer starts. Eon: not changed by the reference
Read timeout1000 ms per read

Confidence: likely.

Session

Solution

The Solution transfer is a lock-step byte dialogue. Every step is host-driven; the device echoes a fixed byte or a triplet before each data byte.

H→D  FF
D→H  3F
H→D  4D 01 01
repeat for i = 1 .. 255:
    D→H  01 <i> <value>        announce address i and its value
    H→D  <i>                   acknowledge the address
    D→H  <value>               value again
    H→D  0D                    carriage return, request next
D→H  02 00 80                  end of memory
H→D  80
D→H  80
H→D  20
D→H  3F                        idle prompt again

Memory address 0 is never transmitted; treat it as 00. The reference implementation only warns (does not abort) when the fixed bytes differ from the expected values, and when the two copies of a value disagree.

Eon generation

H→D  50                        ASCII 'P'
D→H  <2304 bytes memory> <sum8>

The reply is 2305 bytes. The device sends it as a continuous stream; the host should keep reading until all 2305 bytes have arrived (read in whatever chunk size the port delivers).

Two optional configuration writes exist; neither produces a reply in the reference:

PurposeH→D bytes
Set the owner name / personal text4E (‘N’) followed by exactly 20 bytes of text, zero-padded
Set the profile sample interval54 (‘T’) followed by one byte: the interval in seconds

Confidence: likely.

Commands

CommandH→D bytesArgumentsD→H responseNotes
Solution: start dumpFF, then 4D 01 01nonesee Sessionbyte-by-byte dialogue
Eon: dump memory50none2304 data bytes + 1 checksum
Eon: write name4E <20 bytes>textnoneconfiguration only
Eon: write sample interval54 <s>secondsnoneconfiguration only

Framing and integrity

The Solution transfer has no checksum; integrity relies on the double transmission of each value.

The Eon reply ends with an 8-bit additive checksum: the low 8 bits of the sum of the 2304 memory bytes (initial value 0, no final XOR). See ../common/checksums.md#sum8. A mismatch MUST be treated as a failed download.

Worked example of the sum: memory bytes 00 01 02 … 0F followed by 2288 zero bytes give a checksum byte of 78.

Confidence: likely.

Memory layout

Solution (256 bytes)

AddressContents
0x00not transmitted
0x18u8: address of the end-of-profile marker inside the ring
0x1D..0x1Fserial number, 3 × bcd8, most significant first (6 decimal digits)
0x20..0xFFprofile ring buffer (224 bytes)

Eon generation (2304 bytes = 0x900)

AddressContents
0x000..0x0FFsettings and device data
0x0F4..0x0F6serial number, 3 × bcd8 (6 decimal digits)
0x100..0x8FFprofile ring buffer (2048 bytes)

There is no explicit end-of-profile pointer; the host scans the ring from 0x100 upwards for the first 82 byte.

Ring buffer markers

ByteMeaning
82end-of-profile: the write position. Exactly one is expected in the ring
80end of one dive’s samples

Confidence: likely.

Download procedure

Eon: walking the ring

Dives are stored in forward order. The newest dive ends just before the 82 marker. Each dive’s samples end with 80 and are followed by two trailer bytes (temperature, end pressure), so the first byte of a dive sits three bytes after the previous dive’s 80.

eop := first address a in [0x100, 0x900) with mem[a] = 0x82, else error
prev := eop
cur  := eop
repeat at most 2048 times:
    cur := cur - 1, wrapping from 0x100 to 0x8FF
    if mem[cur] = 0x82: stop (whole ring visited)
    if mem[cur - 3 (wrapping)] = 0x80:
        dive := bytes from cur up to (not including) prev, wrapping at 0x900 -> 0x100
        emit dive (newest first)
        prev := cur
end: the walk must terminate on the 0x82 marker, otherwise the image is corrupt

Incremental download: the 5 bytes at dive offset 6 (the start date and time) identify a dive. Stop when they equal the stored fingerprint of the newest dive from the previous download.

Solution: walking the ring

The Solution stores its profile backwards. Starting at the address held in 0x18 (which must point at an 82 byte inside 0x20..0xFF), walk forwards through the ring, wrapping from 0xFF to 0x20, collecting bytes into a buffer that is filled from its end so that the bytes come out reversed (i.e. in chronological order). A dive boundary is reached when the byte two positions ahead of the current one (with wrap-around) is 80; at that point the collected bytes since the previous boundary form one dive. Stop at the next 82.

There is no fingerprint for the Solution; the host has no date to compare.

Confidence: likely. The Solution walk was transcribed from a single implementation and has not been checked against a dump; see open questions.

Dive data format

All depths are in feet, stored as signed 8-bit deltas relative to the previous sample; convert with 1 ft = 0.3048 m. The running depth starts at 0.

Solution dive

OffsetTypeMeaning
0x00..0x023 bytesnot decoded (no date is known to be stored)
0x03..samplesuntil the 80 byte
marker + 1u8extra minutes to add to the dive time

Sample bytes, one per 3-minute interval:

ValueMeaning
00..7D, 83..FFdepth delta, i8, feet
7D or 83as above, and the next byte is a second i8 delta to add (ascents/descents above 124 ft)
7Edeco / ascent warning (“ASC”)
7Fceiling violation (“ERR”)
81slow-down (ascent rate) warning
80end of samples
82end-of-profile (never inside a dive)

Note that 7D and 83 are ordinary deltas of +125 / −125 ft that additionally pull in an extension byte.

Dive time in seconds = (number_of_depth_samples × 3 + mem[marker + 1]) × 60. Gas: always air (21 % O2). No temperature, no tank pressure.

Eon dive

OffsetTypeRaw unitMeaning
0x03u8ssample interval
0x04u8flagsbit 7 set: nitrox dive (Solution Nitrox / Vario); other bits not decoded
0x05u8see rightnitrox dive: O2 percent. Otherwise: tank start pressure, 2 bar per unit
0x06..0x0A5 × bcd8year (2 digits), month, day, hour, minute
0x0B..samplesuntil the 80 byte
marker + 1u8°C + 40minimum (bottom) temperature: subtract 40
marker + 2u82 bartank end pressure (not meaningful for nitrox dives)

Bytes 0x00..0x02 are not decoded. Two-digit years below 85 are 20xx, otherwise 19xx. Seconds are not stored. The time is local time of the device with no time zone.

Gas mix: O2 21 % unless the nitrox flag is set, then the value at 0x05. A start and end pressure of 0 means no tank pressure information.

Sample bytes, one per sample interval:

ValueMeaning
00..7C, 83..FFdepth delta, i8, feet
7Dsurfaced event
7Edeco / ascent (“ASC”) warning
7Fceiling violation (“ERR”)
81slow (ascent rate) warning
80end of samples

Event bytes do not advance time: a time step is only taken when a depth byte arrives, so a run of events followed by a depth delta all belong to the same sample. Dive time = number of depth bytes × sample interval. Implementations typically add an artificial 0 ft point at time 0 and another 0 ft point one interval after the last sample.

Confidence: likely.

Spyder variant of the Eon dive

The Spyder (a Vyper-family device, see suunto-vyper.md) stores dives in the Eon layout above with these differences:

  • the date bytes at 0x06..0x0A are plain binary, not BCD; two-digit years below 90 are 20xx;
  • the temperature at marker + 1 is a signed i8 in °C (no +40 offset);
  • the nitrox flag is not used; 0x05 is always start pressure.

Confidence: likely.

Model-specific variations

  • Solution: 256-byte memory, per-byte handshake, backwards-stored profile, 3-minute fixed sample interval, no date.
  • Eon / Solution Alpha / Solution Nitrox: 2304-byte memory in one reply with sum8, forward profile, configurable sample interval, BCD date.

Open questions

  1. Solution dives carry no date or time in the decoded bytes; whether bytes 0x00..0x02 of a Solution dive hold anything useful (e.g. surface interval) is unknown.
  2. The Solution ring walk (boundary when the byte two ahead is 80) has not been confirmed with a real memory image.
  3. The meaning of the remaining bits of byte 0x04 and of bytes 0x00..0x02 in Eon dives is unknown.
  4. Whether the Eon needs DTR asserted (to power the interface) is not stated by the reference; the Solution path asserts it explicitly.
  5. The ‘N’ and ‘T’ configuration writes are not acknowledged in the reference; whether the device sends anything back is unknown.

References