Suunto D9 / Vyper 2 family (D-series, i-series, Vyper 2, Cobra 2/3, Vyper Air, HelO2)

Suunto’s third-generation wired-interface computers (roughly 2004–2018). All share one packet protocol: a command byte, a 16-bit big-endian length, parameters, and an XOR checksum, over a half-duplex serial cable switched with RTS. Memory is read in blocks of up to 120 bytes. Dives live in a ring buffer as a doubly linked list whose head pointers are in a fixed header block.

Two link variants exist, differing only in how the host drives the cable:

VariantDevicesSpeedEchoRTS while sending
V2 (“Vyper 2 link”)Vyper 2, Cobra 2, Vyper Air, Cobra 3, HelO29600noasserted
D9 (“D-series link”)D9, D6, D4, and the i-series (D4i, D6i, D9tx, DX, Vyper Novo, Zoop Novo, D4f)9600 (classic D) or 115200 (i-series)yes, interface echoes every command bytecleared

Commands, framing, memory layout and dive format are common to both variants. Dive record layouts differ by model group (classic, D4, HelO2, i-series, DX).

Devices

VendorModelModel codeLink variantMemory layoutDive group
SuuntoD90x0ED9, 960032 KiBclassic
SuuntoD60x0FD9, 960032 KiBclassic
SuuntoVyper 20x10V232 KiBclassic
SuuntoCobra 20x11V232 KiBclassic
SuuntoD40x12D9, 960032 KiBD4
SuuntoVyper Air0x13V232 KiBclassic
SuuntoCobra 30x14V232 KiBclassic
SuuntoHelO20x15V232 KiB, HelO2 fingerprintHelO2
SuuntoD4i (also “D4i Novo”)0x19D9, 11520064 KiBi-series
SuuntoD6i (also “D6i Novo”)0x1AD9, 11520064 KiBi-series
SuuntoD9tx0x1BD9, 11520064 KiBi-series
SuuntoDX0x1CD9, 11520064 KiB, DX fingerprintDX
SuuntoVyper Novo0x1DD9, 11520064 KiBi-series
SuuntoZoop Novo0x1E, 0x1FD9, 11520064 KiBi-series
SuuntoD4f0x20D9, 11520064 KiBi-series

The model code is byte 0 of the version reply (see Session).

Identification: wired only, through Suunto’s USB interface cable (an FTDI USB-serial bridge; one source associates FTDI product ID 0403:F680 with it, unconfirmed). See ../transports/.

Confidence: likely.

Transport parameters

Common: 8 data bits, no parity, 1 stop bit (8N1), no flow control. DTR is asserted for the whole session (it powers the interface) and cleared at the end. After asserting DTR, wait, then purge both directions before the first command.

ParameterV2 variantD9 variant
Baud rate96009600 for D4/D6/D9, 115200 for i-series
Read timeout3000 ms (reference)3000 ms (reference); 600 ms (other source)
Settle after DTR100 ms (reference); 1000 ms (other source)same
Before each commandwait ≥ 600 ms (reference) or ≥ 680 ms since previous command (other source)≥ 200 ms since previous command (other source, classic D only); none (reference)
Send sequenceassert RTS, write, wait until the bytes have left the UART, clear RTS, read replyclear RTS, write, read and verify the echo, assert RTS, read reply
Echononeexact copy of the command

Waiting until the bytes have left the UART (V2): the reference computes bytes × 10 bits / 9600 baud + 2 ms from the moment the write started and sleeps for the remainder; the other source sleeps 5 ms before and 15 ms after the write. Both clear RTS before reading.

D9 variant, other source: after the write it sleeps 8 ms and then asserts RTS, reading the echo together with the reply.

Speed autodetection (D9 variant). A host that does not know the model can try the version command at 9600 baud and, on failure, at 115200 baud (try 115200 first when the user selected an i-series model). The successful speed is used for the rest of the session.

Confidence: likely for line settings, RTS polarity and echo behaviour; uncertain for exact delays.

Session

open port 8N1, assert DTR, settle, purge
H→D  0F 00 00 0F                       version
D→H  0F 00 04 <model> <fw2> <fw1> <fw0> <xor>
  • model: model code (table above).
  • fw2 fw1 fw0: firmware version, 24-bit big-endian (one source only uses it for i-series).

Then read the serial number: 4 bytes at 0x0023 (classic, D4, HelO2, V2 devices) or 0x0024 (i-series and DX). Each byte is a value 0..99; concatenate them as two-digit decimal groups (e.g. 0C 22 38 01 → 12345601). The reference reads 8 bytes there and uses the first 4.

There is no explicit logout; clear DTR and close.

Confidence: likely.

Commands

CommandH→D bytesArgumentsD→H responseNotes
Version0F 00 00 0Fnone0F 00 04 <4 bytes> <xor>8 bytes
Read memory05 00 03 AH AL N <xor>16-bit address, N ≤ 120 (0x78)05 LH LL AH AL N <N bytes> <xor>LH LL = N + 3
Write memory06 LH LL AH AL N <N bytes> <xor>address, N ≤ 120, data; LH LL = N + 306 00 03 AH AL N <xor>not needed for download
Set clock10 00 07 YH YL MM DD hh mm ss <xor>year u16be, month, day, hour, minute, second10 00 01 <status> <xor>status = 01 on success
Reset max depth20 00 00 20none20 00 00 20clears the stored maximum depth

Response validation (all commands):

  1. Byte 0 equals the command byte.
  2. Bytes 1–2, as u16be, plus 4 equals the total response length.
  3. The parameter bytes that the response repeats (for a read: address and count) equal the request.
  4. The last byte equals the XOR of all preceding response bytes.

A failed exchange (timeout or validation failure) may be retried; the reference retries twice (three attempts), the other source up to 16 times with 50 ms pauses.

Confidence: likely. The read-reply length bytes are given by the reference as N + 3; the other source describes the reply header as a copy of the request (05 00 03 …). See open questions.

Framing and integrity

<cmd:1> <len:2, u16be> <payload:len> <xor:1>

len counts only the payload. The checksum is the 8-bit XOR of every preceding byte of the packet, initial 00 (../common/checksums.md#xor8; test vector: ASCII 123456789 → 31).

On the D9 variant the host first receives an exact echo of the command (same length), which MUST be checked and discarded before the response.

Worked example (read the 8-byte ring header at 0x0190, D9 variant at 9600 baud):

H→D  05 00 03 01 90 08 9F
D→H  05 00 03 01 90 08 9F                         echo
D→H  05 00 0B 01 90 08 9A 01 05 00 10 20 9A 01 A2
     │  └len=11┘ addr  N  └──── 8 data bytes ───┘ xor

Set-clock example for 2026-11-24 12:34:56:

H→D  10 00 07 07 EA 0B 18 0C 22 38 FF

Confidence: likely.

Memory layout

ItemClassic, D4, V2 devicesHelO2i-seriesDX
Memory size0x80000x80000x100000x10000
Serial number0x00230x00230x00240x0024
Ring header0x01900x01900x01900x0190
Profile ring0x019A..0x7FFD0x019A..0x7FFD0x019A..0xEBEF0x019A..0xEBEF
Fingerprint (offset in dive data, 7 bytes)0x110x170x130x17

The ring’s exclusive end is 0x7FFE (32 KiB devices) or 0xEBF0 (64 KiB devices).

Ring header at 0x0190 (8 bytes)

OffsetTypeMeaning
0x0190u16leaddress of the start of the newest dive
0x0192u16lenon-zero when the ring holds data (disambiguates full vs. empty when the two pointers below are equal)
0x0194u16leend pointer: address just past the newest dive (write position)
0x0196u16lebegin pointer: start of the oldest data still in the ring

The newest-dive and end pointers MUST lie inside the ring. If the begin pointer is outside the ring, treat the whole ring as occupied.

Dive record in the ring

+0  u16le  address of the previous (older) dive record
+2  u16le  address of the next (newer) record, i.e. the end of this one
+4  ...    dive data (header, sample configuration, samples)

The dive data passed to the parser below starts at +4; all dive-data offsets in this document are relative to that point. (Offsets measured from the record start are 4 larger.)

Confidence: likely (the pointer roles agree between sources; the meaning of 0x0192 and the begin pointer comes from the reference only).

Download procedure

read version, choose layout from model code
read serial number
hdr := read 8 bytes at 0x0190
last, count, end, begin := hdr as four u16le
check last and end inside ring
if begin inside ring:
    total := ring distance from begin to end
             (if begin = end: full ring when count ≠ 0, else empty)
else:
    total := ring size
current := last ; following := end
while total > 0:
    size := ring distance from current to following, counting a full ring when equal
    if size < 4 or size > total: error
    read `size` bytes ending at `following`, walking backwards through the ring
         in blocks of ≤ 120 bytes and wrapping from ring start to ring end
    prev := u16le at record+0 ; next := u16le at record+2
    check prev and next inside ring
    if next ≠ following and next ≠ current: error
    if next = current:
        the dive is incomplete (still being written); skip it, report a data error at the end
    else:
        if dive data[fp .. fp+7] = stored fingerprint: stop
        emit dive data (record from +4)
    total := total - size
    following := current ; current := prev

Ring distance from a to b is b - a if b ≥ a, else (ring_end - a) + (b - ring_start).

Stopping on age: instead of the fingerprint, a host may compare the dive’s start time with the newest already-downloaded dive and stop at the first dive that is not newer. One source does this; it also stops when the previous-dive pointer equals the current position or falls inside the newest dive (wrap-around overlap).

Incremental fingerprint: the 7 date/time bytes at the model’s fingerprint offset.

Confidence: likely.

Dive data format

Offsets below are relative to the start of the dive data (record +4).

Header: common fields

OffsetTypeRaw unitConversionMeaning
0x00u8not decoded
0x01u32lelogbook format ID (selects sub-layouts, see below)
0x09u16lecm/ 100 → mmaximum depth

Header: fields that move by model group

FieldClassicD4HelO2i-seriesDX
Dive time: offset0x0B0x0B0x0D0x0D0x0D
Dive time: unitminutessecondsminutessecondsseconds
Date/time offset0x110x110x170x130x17
Date/time orderh, m, s, year u16le, month, daysame as classicsame as classicyear u16le, month, day, h, m, ssame as i-series
Gas mode byte0x190x190x1F0x1D0x21
Sample interval (s)0x180x180x1E0x1E0x22
Conservatism0x1E (raw)0x1E (raw)0x23 (raw − 2)0x21 (raw − 2)0x25 (raw − 2)
Gas table offset0x210x210x540x5F or 0x670xC1 or 0xC3
Gas table entries3 × 1 byte3 × 1 byte8 × 6 bytes1, 2, 3 or 8 × 6 bytes11 × 6 bytes
Initial gas index000x260x28 or 0x2D0x31
Sample configuration offset0x3A0x3Btable endtable endtable end

“Table end” = gas table offset + entries × 6.

One source gives surface-interval hours and minutes at 0x1B/0x1C (classic, D4, i-series) and at date offset + 10/11 (HelO2) or + 8/9 (DX); the reference does not decode them.

Logbook format IDs (u32le at 0x01)

IDSeen onEffect
0x1871C062D4i / D6i, first format, D6i with 2 mixesgas table at 0x5F, initial gas at 0x28
0x1871C063D6i, first format, 3 mixesgas table at 0x5F, 3 entries, initial gas at 0x28
0x18724062D4i / D6i, second formatgas table at 0x67, initial gas at 0x2D; D6i: 5-byte gas-change events
0x18922062DX, first formatgas table at 0xC1
0x18924062DX, second formatgas table at 0xC3

i-series gas-table entry counts: D4i, Zoop Novo, D4f → 1; D6i and Vyper Novo → 3 with IDs 0x1871C063/0x18724062, else 2; D9tx → 8 (table at 0x87, independent of ID).

Gas mode byte

ValueMode
0air: one mix, 21 % O2
1nitrox
2gauge: no mixes
3free dive: no mixes
4mixed gas (trimix)
5closed circuit (DX)

Gas table

  • Classic and D4: up to 3 single bytes, each an O2 percentage; a 00 or FF ends the list.
  • All other groups: 6-byte entries; byte +1 is O2 %, byte +2 is He %; the other four bytes are not decoded. All listed entries count, including unused ones.
  • DX: the first 3 entries are closed-circuit diluents, the remaining 8 open-circuit gases. Initial gas byte at 0x31: low 7 bits are an index; if bit 7 is clear the index is into the open-circuit part (add 3), if set it is into the diluent part.

Applies only when the mode is not air, gauge or free dive.

Sample configuration and profile

At the sample configuration offset c:

c + 0        u8   n, number of sampled channels (1..3)
c + 1        u8   not decoded
c + 2 + 3k   3 bytes per channel k:
               +0  channel type
               +1  period: sampled on every tick whose index is a multiple of this (0 = never)
               +2  flags: bits 2..4 select a divisor from {1, 2, 4, 5, 10, 50, 100, 1000}
p = c + 2 + 3n   profile block

Channel types:

TypeSizeMeaningConversion
0x64u16ledepthraw / divisor → m
0x68u16letank pressure; FFFF = no readingraw / divisor → bar
0x74i8temperatureraw / divisor → °C

Any other type is an error (the record cannot be parsed).

HelO2 only: if the three bytes at p are not 01 00 00, an extra 12-byte block precedes the profile; add 12 to p.

p + 0..2   01 00 00        (looks like an initial event-block terminator, see below)
p + 3      u16le           tick index at which the first event block appears ("marker")
p + 5 ...  ticks

Ticks: tick t (starting at 0) is at time t × sample interval seconds. For each tick, for each channel in configuration order whose period divides t, read that channel’s value. After the channel values, if t + 1 equals the current marker, an event block follows.

Event block

A sequence of events, terminated by event 01:

CodeLength after codeFieldsMeaning
014u16le current, u16le deltaend of block. current MUST equal the marker; the new marker = marker + delta
022state, secondssurfaced
032type, secondswarning / state change; bit 7 of type set = condition ended, clear = began
044number, seconds, u16le headingheading FFFF: bookmark; otherwise compass bearing, heading / 2 = degrees
052O2 %, secondsgas change to the listed mix with that O2 (He 0)
064 or 5type, He %, O2 %, [ppO2], secondsgas change by index; 5 bytes on DX, Vyper Novo, and D6i with format ID 0x18724062

seconds is the offset of the event within the current tick.

Event 06 details: low nibble of type is the gas index; bit 7 clear means an open-circuit gas (on the DX add the 3 diluent slots), bit 7 set means a diluent, in which case ppO2 / 10 is the new set point in bar. The He and O2 bytes must match the gas table entry.

Event 03 type codes (low 7 bits):

CodeMeaning
00voluntary safety stop
01mandatory safety stop
02deep stop
03decompression
04ascent rate warning
05ceiling broken
06mandatory safety stop ceiling error
07below deco floor
08dive time alarm
09depth alarm
0Aoxygen limit fraction 80 %
0Boxygen limit fraction 100 %
0CppO2 warning
0Dair time warning
0ERGBM warning
0FppO2 high
10ppO2 low
11tissue level warning
12tissue calculation overflow
13deep stop
14mandatory safety stop

Codes 00–03, 13, 14 are states (stop in progress / deco in progress) rather than alarms; a host can derive the current deco state from them (deep stop > deco > safety stop > no-deco).

An unknown event code has unknown length; the reference continues after the code byte, which may desynchronise. Treat it as a parse error unless more is known.

Tank start/end pressure is not in the header; derive them from the first and last (or highest and lowest) valid pressure samples.

Date and time

Local device time, second resolution, full 16-bit year (little-endian), no time zone.

Confidence: likely for offsets that both sources give (most of the header, the channel types, event codes 01, 03, 05); uncertain for event 02 and 04 (one source reads 02 as surfaced and 04 as bookmark/heading, the other leaves them undecoded), for the HelO2 12-byte block, and for the 5-byte 06 rule.

Model-specific variations

  • V2 link (Vyper 2, Cobra 2/3, Vyper Air, HelO2): no echo, RTS asserted while sending.
  • D9 link (D9, D6, D4, i-series): echo, RTS cleared while sending; i-series at 115200 baud.
  • D4: dive time in seconds and sample configuration one byte later than classic.
  • HelO2: trimix gas table, optional extra 12-byte block before the profile.
  • i-series and DX: 64 KiB memory, serial at 0x0024, year-first date.
  • DX: closed-circuit diluents and set points.

Open questions

  1. Read-reply bytes 1–2: the reference requires 00 (N+3); the other source describes them as 00 03. The reference’s rule is consistent with the version reply (00 04 for 4 data bytes).
  2. Meaning of the ring header word at 0x0192 (a dive count?) and of dive-data byte 0x00.
  3. The 12-byte HelO2 block and the four undecoded bytes of each 6-byte gas entry.
  4. Exact required inter-command delays and DTR settle time; the sources differ by up to 10×.
  5. Lengths of unknown event codes.
  6. Whether the Zoop Novo’s two model codes (0x1E, 0x1F) differ in anything else.

References