Halcyon Symbios

The Halcyon Symbios system has a handset dive computer and a heads-up display (HUD). Both talk Bluetooth Low Energy. The host sends one-byte commands, with an optional payload protected by a CRC-8. Responses carry the command with bit 7 set, an ACK/NAK byte and a CRC-8. Large objects (the logbook and each dive log) come as a stream of numbered blocks of up to 200 bytes. The host acknowledges each block with ACK and asks for a resend with NAK. A dive log is a sequence of type-length records.

Devices

VendorModelModel codeTransports
HalcyonSymbios HUD1BLE
HalcyonSymbios Handset7BLE

The model code is byte 5 of the status response and byte 2 of the dive header record.

BLE advertised name, two forms:

  • starts with H followed by the two-digit model code (H01…, H07…), case-insensitive; or
  • at least 10 characters, all decimal digits, with characters 4..5 equal to the two-digit model code (for example xxxx07xxxx for a handset).

GATT (public open-source BLE table):

RoleUUID
Service00000001-8c3b-4f2c-a59e-8c08224f3253
Device → host (notify)00000101-8c3b-4f2c-a59e-8c08224f3253
Host → device (write)00000201-8c3b-4f2c-a59e-8c08224f3253

The device uses a random (private) BLE address.

Confidence: likely. The characteristic roles come from one source, which excludes …0101 as a write target and …0201 as a notify source.

Transport parameters

  • One protocol packet per BLE write or notification. Packets are at most 1 + 256 + 1 bytes (host) or 2 + 256 + 1 bytes (device). A 200-byte data block needs 205 bytes, so the link needs an ATT MTU of at least 208.
  • Response timeout: 5000 ms. One reference implementation uses 3000 ms, and a later fork of it raised the value to 5000 ms.
  • Flush input after connecting.

Confidence: likely.

Session

No handshake. Known hosts first send get status (01). The response payload (20 to 36 bytes) is:

OffsetTypeMeaning
0x00u32leserial number
0x04u8hardware version
0x05u8model code
0x06u8Bluetooth firmware major
0x07u8Bluetooth firmware minor
0x08u16lebattery
0x0Au16lepressure
0x0Cu32leerror bits
0x103 × u8firmware major, minor, patch
0x13..not decoded

Confidence: likely.

Commands

CmdFunctionRequest payloadResponse payload
01get status—20-36 bytes, see above
02get settings—(not used by known hosts)
03set settings—(not used by known hosts)
04request logbook—u32le total logbook length; data follows as 08 blocks
05request dive logu16le dive id (from the logbook)u32le total length; data follows as 09 blocks
07set timeyear−2000, month, day, hour, minute, secondempty
08logbook data block(host sends bare 08 to start)block, see below
09dive log data block(host sends bare 09 to start)block, see below
06ACK (host → device)—next block, or nothing after the last block
15NAK (host → device)—resend of the current block

NAK error codes (byte 2 of a NAK response):

CodeMeaning
0CRC error
1boundary error
2wrong command length
3unknown command
4timeout
5file not found / empty. For request logbook this means “no dives”. For request dive log the host skips that dive
6unknown error

Confidence: likely. The settings commands are known by number only.

Framing and integrity

Host → device:

cmd                                    (no payload: a single byte, no CRC)
cmd  payload[n]  crc8(payload)         (n ≥ 1)

The CRC covers the payload only, not the command byte.

Device → host:

(cmd | 0x80)  06  payload[n]  crc8(bytes 1 .. 1+n)      ACK response
(cmd | 0x80)  15  errcode     crc8(bytes 1 .. 2)        NAK response (always 4 bytes)

The device CRC covers everything after the command byte: the ACK/NAK byte and the payload. A response has at least 3 bytes.

CRC: CRC-8/SMBUS: width 8, poly 0x07, init 0x00, refin false, refout false, xorout 0x00. Check value for "123456789" = 0xF4. See ../common/checksums.md#crc-8-smbus.

Block transfer

After a request (04 or 05) the device answers with ACK and a 4-byte u32le total length. Then:

  1. The host sends the bare block command (08 or 09).
  2. The device sends a block response: (block cmd | 0x80) 06 <u16le id> <data…> crc8.
    • id bits 0-14: sequence number. It starts at 1 and increments by 1 per block, wrapping at 0x7FFF.
    • id bit 15: set on the last block.
    • Up to 200 data bytes per block.
  3. After a good block the host sends 06 (ACK). After the last block the ACK finishes the transfer.
  4. On a CRC error or a timeout the host sends 15 (NAK), and the device repeats the block. Known hosts retry up to 3 times. On a timeout, wait briefly (about 300 ms) and flush input before sending NAK, so that a late copy of the block is not taken as the resend.
  5. The total data length MUST equal the announced length.

Worked examples

H→D  07 18 03 0F 0A 14 1E 7B     set time 2024-03-15 10:20:30; CRC-8 of the 6 bytes = 0x7B
D→H  87 06 12                    ACK, empty payload; CRC-8(06) = 0x12
H→D  05 05 00 41                 request dive log id 5 (u16le 0x0005), CRC-8(05 00) = 0x41
D→H  85 06 L0 L1 L2 L3 <crc>     total length
H→D  09                          start block stream
D→H  89 06 01 00 <≤200 bytes> <crc>
D→H  84 15 05 0D                 example NAK to request logbook: error 5 (no dives), CRC-8(15 05) = 0x0D
H→D  06                          ACK …

Confidence: likely.

Memory layout

No raw memory access. The logbook is a flat array of 32-byte entries, oldest first. Dive logs are fetched by dive id.

Logbook entry (32 bytes):

OffsetTypeMeaning
0x10u16ledive id (argument for command 05)
0x144 bytesfingerprint
othernot decoded

Download procedure

status = get_status()
logbook = block_download(04, 08)       # NAK code 5 → no dives, done
entries = split logbook into 32-byte entries
walk entries from the LAST to the first:
    if entry[0x14..0x17] == known_fingerprint: stop
    log = block_download(05 with entry[0x10..0x11], 09)
          # NAK code 5 → skip this entry
    hand log to the parser with fingerprint entry[0x14..0x17]

Confidence: likely.

Dive data format

The dive log is a sequence of records:

u8 type   u8 length (whole record, including these 2 bytes; ≥ 2)   payload…

Unknown types are skipped by their length. For known types the length MUST match the table.

TypeLengthContent (offsets from record start)
0x01 header64see Header
0x02 gas switch4+2 O2 %, +3 He %
0x03 depth4+2 u16le depth, cm
0x04 temperature4+2 u16le temperature, 0.1 °C
0x05 OC/CC switch4+2 u8 mode (not decoded further)
0x06 gas transmitter12+2 u8 gas id, +4 u16le transmitter battery, +6 u16le tank pressure 0.1 bar, +8 u16le transmitter id
0x07 compartments68+4 16 × u16le N2 loadings, +36 16 × u16le He loadings
0x08 GPS12+4 i32le longitude, +8 i32le latitude, 1e-6 degrees
0x09 ppO2 (board)8+2..+4 3 × u8 ppO2, 0.01 bar; +6 u16le board serial
0x0A deco16+2 u8 NDL min, +3 u8 ceiling m, +4 u8 CNS %, +5 u8 safety stop, +6 u16le maximum ceiling, +8 u16le time to surface, +10 u16le OTU
0x0B gradient factors4+2 GF low %, +3 GF high %. Only the first record counts
0x0C footer16+2 u8 CNS %, +3 u8 violations, +4 u16le OTU, +6 u16le battery, +8 u32le end time (same epoch as start), +12 u32le desaturation time
0x0D ppO2 (rebreather)12+2..+4 3 × u8 ppO2 0.01 bar, +8 u16le oxygen tank pressure 0.1 bar, +10 u16le transmitter serial
0x0E compass4+2 u16le heading, degrees
0x0F log version4+2 major, +3 minor
0x10 trim4+2 i8 trim angle
0x11 gas configuration8+2 gas id, +3 O2 %, +4 He %, +5 enabled flag
0x12 tank transmitter8+2 u8 transmitter id, +4 u16le battery, +6 u16le pressure 0.01 bar
0x13 GF info (old)6+2 u16le current GF, +4 u16le surfacing GF
0x14 gas consumption4+2 u16le SGC
0x15 GF data8as 0x13, plus +6 u8 leading-tissue current GF, +7 u8 leading-tissue surfacing GF

Known firmware bug: before log version 1.12, some firmware wrote type 0x15 records with the old 6-byte length. Treat a type-0x15 record of length 6 as type 0x13.

Record type 0x01, 64 bytes:

OffsetTypeRaw unitMeaning
+2u8model code
+3, +4u8, u8hardware major, minor
+5..+73 × u8firmware major, minor, patch
+8, +9u8, u8decompression algorithm version
+10u8ssample interval
+11u8dive detection setting
+12u8no-fly time
+13u8dive mode: 0 OC, 1 CCR, 2 CCR with fixed setpoint, 3 sidemount (OC), 4 gauge
+14i8hUTC offset
+16u16lembarsurface pressure
+18u16ledive number
+20u16lebattery
+22u16leminsurface time inside the dive (see Open questions)
+24u32lesstart time, seconds since 2021-01-01 00:00:00
+28u32leserial number

Samples

Records appear in time order. The header, footer and log-version records are configuration records and carry no time. Time advances by the sample interval at each depth record, except the first. The first non-configuration record sets the first sample time (one interval). Maximum depth is the largest depth record value.

Gas mixes:

  • Gas configuration (0x11) defines gases by id. A slot with O2 = He = 0 is empty. Gas ids 0-4 are open-circuit gas slots, and ids 5 and up are diluents.
  • Gas switch (0x02) gives an active gas by its mixture.
  • The gas id in a gas-transmitter record (0x06) also names the active gas.
  • Hosts differ on gases that are configured but disabled: one includes every non-empty slot, another includes only enabled slots and diluents (see Open questions).

Tank pressures come from record types 0x06 (0.1 bar), 0x0D (0.1 bar, oxygen bottle) and 0x12 (0.01 bar). Tanks are told apart by transmitter id. Ids from type-0x12 records should be kept in a separate namespace from type-0x06 ids. Begin pressure is the first reading and end pressure is the last.

Dive time is end time (footer) − start time (header). One implementation also subtracts the surface time at header +22. If either time stamp is missing, use the last sample time.

Date and time

Start time is a u32le count of seconds since 2021-01-01 00:00:00 (Unix 1609459200).

  • Log version 1.9 or later: the count is UTC. Local time = count + (header +14) × 3600 s.
  • Earlier logs: no zone information. Known hosts convert the count as UTC to the host’s current time zone. This is a host convention, not a device fact.

Confidence: likely for the record layout. Uncertain for the time-to-surface unit, the deco ceiling unit (assumed metres), and the surface-time subtraction.

Model-specific variations

  • The HUD (model 1) and handset (model 7) share the protocol. Which record types each one writes is not documented.
  • Log versions: 1.9 introduces the UTC offset and the 0x15 GF data record. 1.12 fixes the 0x15 length bug.

Open questions

  1. Surface time. One implementation subtracts header +22 (minutes) from end − start to get the dive time. Another ignores it. Which is right?
  2. Disabled gas slots. A gas-transmitter record can reference a slot whose configuration record had the enabled flag cleared. Implementations differ on whether such gases appear in the gas list.
  3. The unit of the time to surface (deco record +8): seconds or minutes.
  4. The unit of the ceiling (deco record +3): assumed whole metres.
  5. Get/set settings payload formats.
  6. Whether the ATT MTU is negotiated by the device or must be requested by the host.