Divesoft Freedom dive computers and the Liberty closed-circuit rebreather controller store each dive as a binary log made of a fixed header followed by 16-byte records. The same log can be fetched two ways:

  1. Bluetooth Low Energy (Bluetooth-capable hardware revisions). The host talks a message protocol: messages split into fragments, each fragment protected by a CRC-16 and wrapped in byte-stuffed 7E frames.
  2. USB mass storage (all hardware revisions with USB). The computer appears as a disk holding a DIVELOG directory with one .DLF file per dive.

A Divesoft developer has stated publicly that a .DLF file has the same format as a dive downloaded over Bluetooth. The Dive data format section therefore covers both paths.

Devices

VendorModelModel codeTransportsNotes
DivesoftLiberty (CCR controller), hardware 1.x1USB storageno Bluetooth
DivesoftFreedom, hardware 2.x2USB storageno Bluetooth
DivesoftFreedom, hardware 3.x5USB storageno Bluetooth
DivesoftLiberty, hardware 2.x10BLE, USB storage
DivesoftFreedom (incl. Freedom+), hardware 4.x19BLE, USB storage

The model code is byte 0 of the version response (see Commands).

Identification:

  • BLE: the advertised name starts with Freedom or Liberty (case-insensitive prefix match).
  • BLE service UUID 0000fcef-0000-1000-8000-00805f9b34fb (16-bit UUID 0xFCEF).
  • USB mass storage: the USB VID:PID is not known (see Open questions). A host can recognise the volume by its DIVELOG directory of .DLF files.

Confidence: likely (model codes and BLE names from one reference implementation; service UUID from a second open-source project’s BLE table).

Transport parameters

BLE

  • Service 0xFCEF as above. The write and notify characteristics are not documented publicly. Known hosts use the first writable characteristic and the first notify-capable characteristic in that service.
  • The host writes the byte-stuffed frame stream (see Framing) in chunks of at most 244 bytes. Incoming notifications are concatenated and de-stuffed.
  • Receive timeout: 3000 ms per frame.
  • A serial-style line configuration of 115200 8N1 with no flow control is applied, but has no effect on BLE.

USB mass storage

  • A standard USB Mass Storage Class device with a FAT file system; see ../transports/.
  • Dive logs: directory DIVELOG in the volume root, file extension .DLF, one dive per file. File names are 8-digit numbers, for example 00000033.DLF.
  • The volume may also hold non-dive files: a system log (.DSF and .CSV) and a configuration (.DCF and .CSV). Some firmware also writes a .CSV text copy of each dive. A host only needs the .DLF files.

Confidence: likely for BLE parameters; likely for the storage layout (the user manual and an independent implementation agree on the directory and extension).

Session

BLE only:

  1. Open the BLE link and subscribe to notifications.

  2. Send CONNECT (message type 2) with payload u16le compression followed by an ASCII client name with no terminator. Known hosts send compression = 1. The client name is free-form.

  3. The device answers with CONNECTED (type 3), a 36-byte payload:

    OffsetTypeMeaning
    0x00u16lecompression accepted
    0x02u8protocol version, major
    0x03u8protocol version, minor
    0x0416 × ASCIIserial number
    0x1416 bytesnot decoded
  4. Optionally send VERSION (type 4) with an empty payload. The device answers with type 5 and a 26-byte payload:

    OffsetTypeMeaning
    0x00u8model code (see Devices)
    0x01u8hardware version, major
    0x02u8hardware version, minor
    0x03..0x053 × u8firmware version major, minor, patch
    0x06u32lefirmware build number
    0x0A16 × ASCIIserial number. Characters 5..15 are decimal digits that form the numeric serial

No authentication or pairing step is known beyond normal BLE bonding. There is no explicit disconnect message.

Confidence: likely.

Commands

Every request gets exactly one response message. The response type is normally the request type + 1. The dive-list request is the exception: it is answered with type 67 or type 71, depending on the log format version.

RequestTypeRequest payloadResponse typeResponse payload
Echo0not used by known hosts1(generic result)
Connect2u16le compression, ASCII client name336 bytes, see above
Version4empty526 bytes, see above
Dive data64u32le handle, u32le offset, u32le length (12 bytes)65length bytes of the dive log, starting at offset
Dive list66u32le start handle, u8 direction, u8 max count (6 bytes)67 (v1 logs) or 71 (v2 logs)list records, see below

The dive list request:

  • start handle: 0xFFFFFFFF starts at the newest dive. Otherwise give the handle of the last record received in the previous batch.
  • direction: 1 goes from newer to older dives (the only value used by known hosts).
  • max count: known hosts use 100.

The response is a sequence of fixed-size records:

OffsetSizeMeaning
04u32le dive handle
420dive fingerprint (opaque)
2432 (type 67) or 64 (type 71)copy of the dive header (see Header)

Record size is therefore 56 bytes (v1) or 88 bytes (v2). Fewer than max count records means the end of the list has been reached.

Confidence: likely.

Framing and integrity

Two layers sit between a message and the BLE byte stream.

Fragment (message layer)

A message payload is split into fragments of at most 256 payload bytes. Each fragment is:

OffsetSizeMeaning
01bits 0-3: message sequence number (mod 16). Bits 4-7: fragment index within the message (mod 16)
11flags: bit 7 = 1 on host→device fragments. Bit 6 = 1 on the last fragment. All other bits 0
22u16le message type
42u16le payload length of this fragment (n)
6npayload
6+n2u16le CRC over bytes 0..5+n
  • The host keeps a 4-bit message counter. It increments the counter before each request, so the first message after connecting uses sequence number 1. All fragments of a request carry the same sequence number. The fragment index counts 0, 1, 2, … within the message.
  • Device→host fragments echo the request’s sequence number and number their own fragments from 0. They have flags 0x40 on the last fragment and 0x00 otherwise, so bit 7 is clear in that direction. Every fragment of one response carries the same message type.
  • A receiver MUST check the sequence/index byte, the flags, the length field (it equals the fragment size minus 8) and the CRC.

CRC: CRC-16/IBM-SDLC (also known as CRC-16/X-25): width 16, poly 0x1021, init 0xFFFF, refin true, refout true, xorout 0xFFFF. Check value for "123456789" = 0x906E. See ../common/checksums.md#crc-16-ibm-sdlc.

Byte stuffing (frame layer)

Each fragment travels in its own frame:

  • The frame starts and ends with 7E.
  • Inside the frame, each 7E or 7D byte is sent as 7D followed by the byte XOR 0x20. For example, 7E becomes 7D 5E and 7D becomes 7D 5D.
  • A receiver drops bytes before the first 7E. It treats 7E while an escape is pending, or 7D 7D, as a framing error.

There is no address or control field. Despite the HDLC-like stuffing, this is not HDLC framing.

Worked examples

CONNECT, the first message (sequence 1), payload 01 00 + ASCII dcrs:

fragment  01 C0 02 00 06 00 01 00 64 63 72 73 08 78
          |  |  |---| |---| |---------------| |---|
          |  |  type2  len6  payload           CRC 0x7808 (LE)
          |  flags C0: host→device, last fragment
          seq 1, fragment 0
H→D       7E 01 C0 02 00 06 00 01 00 64 63 72 73 08 78 7E

VERSION as message 2: 7E 02 C0 04 00 00 00 42 C6 7E.

First DIVE LIST as message 3 (start FFFFFFFF, direction 1, count 100): 7E 03 C0 42 00 06 00 FF FF FF FF 01 64 01 9B 7E.

Escaping example: the fragment bytes 12 7E 34 7D are sent as 7E 12 7D 5E 34 7D 5D 7E.

Confidence: likely.

Memory layout

Not applicable. The device exposes dives by handle (BLE) or as files (USB storage). It offers no raw memory access.

Download procedure

BLE

connect(); optionally version()
records = []
start = 0xFFFFFFFF
loop:
    batch = dive_list(start, direction=1, max=100)
    for rec in batch:
        if rec.fingerprint == known_fingerprint: stop the whole list
        records.append(rec); start = rec.handle
    if len(batch) < 100: break
for rec in records (newest first):
    n = record count from rec.header (v1: u32le@16 bits 0-17; v2: u32le@20)
    length = header_size + 16 * n          # 32 or 64 + 16n
    dive = dive_data(rec.handle, offset=0, length)
    require dive[0:header_size] == rec.header
    hand dive to the parser; store rec.fingerprint
  • The fingerprint for incremental download is the 20-byte opaque value from the list record. It is not part of the dive bytes.
  • A host can read a dive in pieces by using the offset field. Known hosts read the whole dive at once and let the fragment layer split it.

USB storage

  1. Mount or read the FAT volume and list DIVELOG/*.DLF (case-insensitive).
  2. For a quick “new dives only” filter, read the first 12 bytes of each file. Compare the u32le start time at offset 8 with the newest dive already known. The 20-byte BLE fingerprint is not stored in the file, so a file-based host needs its own fingerprint, for example the header start time or the file name.
  3. Parse each file with the dive data format below.

Confidence: likely for BLE, likely for storage.

Dive data format

A dive log (BLE dive-data payload or .DLF file) is a header followed by 16-byte records. All integers are little-endian.

Two header versions exist, told apart by the first four bytes:

Bytes 0..3ASCIIVersionHeader size
44 69 76 45DivEv132
44 69 56 45DiVEv264

Both versions carry a header checksum at offset 4: a u16le CRC-16/MODBUS (width 16, poly 0x8005, init 0xFFFF, refin true, refout true, xorout 0x0000) computed over header bytes 6 to the end of the header (26 bytes for v1, 58 for v2). Check value for "123456789" = 0x4B37. See ../common/checksums.md#crc-16-modbus.

v1 header (32 bytes)

OffsetTypeRaw unitConversion / meaning
0x004 bytessignature DivE
0x04u16leheader CRC (see above)
0x08u32lesstart time, seconds since 2000-01-01 00:00:00, local time
0x0Cu32lebits 0-16: dive time in s. Bits 27-29: dive mode (table below)
0x10u32lebits 0-17: number of 16-byte records. Bits 18-27: minimum temperature, signed 10-bit, 0.1 °C
0x14u16lecmmaximum depth; m = raw / 100
0x18u16le10 Pasurface pressure; bar = raw / 10000
0x1Au8%initial diluent O2 (CCR modes)
0x1Bu8%initial diluent He (CCR modes)
othernot decoded

v2 header (64 bytes)

OffsetTypeRaw unitConversion / meaning
0x004 bytessignature DiVE
0x04u16leheader CRC
0x08u32lesstart time, seconds since 2000-01-01 00:00:00 UTC
0x0Cu32lesdive time
0x12u8dive mode (table below)
0x14u32lenumber of 16-byte records
0x18i16le0.1 °Cminimum temperature
0x1Cu16lecmmaximum depth
0x20u16le10 Pasurface pressure; bar = raw / 10000
0x26u16lecmaverage depth
0x28i16leminUTC offset of the device clock
0x344 × ASCIIserial number, first part
0x388 × ASCIIserial number, second part
othernot decoded

Dive mode values:

ValueModeCommon model
0unknown—
1open circuitOC
2closed circuitCCR
3manual CCRCCR
4freedivingfreedive
5gauge / bottom timergauge
6active SCRSCR
7passive SCRSCR
8bailout from CCR (open circuit on a CCR dive)CCR

Modes 2, 3, 6, 7 and 8 count as “rebreather” modes for gas-mix interpretation (see events 5/23/24 below).

File length = header size + 16 × record count.

Records

Each record is 16 bytes. Records consisting entirely of FF bytes are padding; skip them. The first u32le of every record is a common word:

BitsMeaning
0-3record class (table below)
4-20time since dive start, s (17 bits)
21-30record identifier (10 bits); meaning depends on the class
31not used

Time stamps should increase. Small backward steps of 1-5 s occur in real logs. Skip records with such a step until time catches up, and treat a larger backward jump as corrupt data.

Record classes:

ClassMeaning
0profile point
1event triggered by a diver action
2automatic event
3diver error / warning
4internal error
5activity event
6configuration
7measurement
8decompression state (tissue loadings)
9information event

Class 0 – profile point

OffsetTypeRaw unitMeaning
+4u16lecmdepth
+6u16le10 PappO2; bar = raw / 10000. 0 = not available

Identifier 0 (and 0x3FF in older firmware) marks the primary point record, which carries more fields. Identifier 1 is a secondary point record whose remaining fields are not decoded.

OffsetTypeMeaning
+8u32lebits 0-9: no-decompression limit, min. Bits 10-19: time to surface, min. Bits 20-29: temperature, signed 10-bit, 0.1 °C
+12u16leceiling, cm. Non-zero means a decompression obligation
+15u8setpoint, 0.01 bar. 0 = none

Classes 1-5 and 9 – events

The event code is u16le at +4. Codes are the same across these classes. The ones with a known payload:

CodeEventPayload
1setpoint changed manually+6 u8 new setpoint, 0.01 bar
2setpoint changed automatically+6 u8 new setpoint, 0.01 bar
5breathing gas changed+6 u8 O2 %, +7 u8 He % (open-circuit gas)
23diluent changed+6 u8 O2 %, +7 u8 He %
24dive mode changed+6 u8 O2 %, +7 u8 He %, +8 u8 new mode. The gas is a diluent if the new mode is a rebreather mode, otherwise an open-circuit gas
26bookmark set by the diver—
30CNS update+6 u16le CNS, %
55waypoint+8 u16le compass heading, degrees. Bit 15 set = no heading

Other codes are warnings and status notifications with no decoded payload: ascent too fast, ceiling broken, ppO2 too high or too low, low battery, O2 sensor problems, solenoid problems, stop completed, depth or time alarms, peer device lost or regained, and similar. The full range seen in the field is 0-59.

Class 6 – configuration

The record identifier selects the content:

IdContent
2O2 sensor calibration: +4 4 × u16le, one per sensor. Each is a ppO2 per millivolt factor; with the mV readings below, ppO2 [Pa] = mV × factor (see id 3 measurement)
3serial number: +4 4 × ASCII, +8 8 × ASCII
4decompression settings: +4 u16le flags (bit 1 = salt water, bit 5 = VPM model; otherwise Bühlmann with gradient factors), +8 u8 GF low %, +9 u8 GF high %
5firmware/hardware version: +4 model code, +5/+6 hardware major/minor, +7..+9 firmware major/minor/patch, +10 u16le flags, +12 u32le build
7gas integration (one record per tank): +4 O2 %, +5 He %, +6 u16le tank volume 0.1 L, +8 u16le working pressure bar, +10 u8 transmitter slot (0-11), +11 u8 gas id (10 = oxygen of the rebreather, 11 = diluent, others = open-circuit gas)
9diluent list: 4 entries of 3 bytes at +4: O2 %, He %, state (bit 0 = enabled, bits 1-7 = gas id)
0, 1, 6, 8rebreather tests, ascent settings, CCR settings; not decoded

Water density: salt water = 1028 kg/m³ and fresh water = 1000 kg/m³ when converting pressure to depth. Depths in the log are already in cm, so this matters only for re-computation.

Known firmware bug in id-7 records: some pre-release versions stored the oxygen and diluent gas ids as 0-9 instead of 10/11. A gas id that is ≤ 9 and not larger than the previous record’s id should be read as id + 10.

Class 7 – measurement

IdContent
0ppO2 per sensor: +4 4 × u16le, 10 Pa (bar = raw / 10000). 0 or FFFF = no value
1battery; not decoded
2helium; not decoded
3O2 sensor millivolts: +4 4 × u16le, 0.01 mV. +12 4 × u8 sensor state. Combine with the class 6 id 2 calibration factor: ppO2 [bar] = (raw / 100) × factor / 100000. Ignore sensors with state 4 (uncalibrated) or 8 (absent), or with a zero factor
4position: +4 i32le latitude, +8 i32le longitude, both in 1e-6 degrees
5ambient pressure; not decoded
6gas consumption (SAC); not decoded
7tank pressures: +4 12 × u8, one per transmitter slot, 2 bar per unit (bar = raw × 2). 0 or FF = no reading
8display brightness; not decoded
9gas-integration status; not decoded

Sensor state values: 0 normal, 1 over range, 2 disabled, 3 excluded, 4 uncalibrated, 5 error, 6 offline, 7 inhibited, 8 not present.

Class 8 – decompression state

Tissue loading snapshots; not decoded. Skip them.

Gas mixes and tanks

A dive’s gas list is assembled from, in this order:

  1. configuration id-7 records (gas integration);
  2. enabled diluents from configuration id-9 records;
  3. the initial diluent from the v1 header, in rebreather modes;
  4. the gases named in events 5, 23 and 24.

Gases are de-duplicated by (O2, He, type), where type is open circuit, oxygen or diluent. Tank pressures (measurement id 7) map to tanks by transmitter slot. A tank’s working-pressure or volume value above 400 bar or 99.0 L means “not set”.

Date and time

  • Start time: u32le at header offset 8, seconds since 2000-01-01 00:00:00 (Unix time 946684800).
  • v1: the value is local wall-clock time; no zone is stored.
  • v2: the value is UTC. Local time = value + (i16le at offset 0x28) × 60 s.

Confidence for the whole dive format: likely (one reference implementation). An independent clean-room reading of .DLF files agrees on the v1 header (start time, duration bits, minimum temperature bits, maximum depth), on the point record (time bits, depth, temperature bits) and on configuration ids 3 and 4. It disagrees on the remaining point-record fields (see Open questions).

Model-specific variations

  • Models 1, 2 and 5 (no Bluetooth) can only be read through USB storage.
  • Log format v1 (DivE, 32-byte header) comes from older firmware. Format v2 (DiVE, 64-byte header) adds UTC offset, average depth and serial number. Over BLE the dive-list response type tells the host which format it will get (67 → v1, 71 → v2).

Open questions

  1. Point record, bytes +12..+15. One implementation reads a u16le ceiling in cm at +12 and a u8 setpoint in 0.01 bar at +15. Another reads u32le at +12 divided by 100 as a decompression stop depth. These agree for small values only if +14/+15 are zero. Needs a real log with deco and a setpoint.
  2. BLE characteristics. The write and notify characteristic UUIDs inside service 0xFCEF, and whether writes need a response, are not publicly documented.
  3. USB VID:PID of the mass-storage interface is not known.
  4. Point record id 1 and many event payloads (warnings, sensor events) are not decoded.
  5. Whether the CONNECT compression value (1) changes the dive-data encoding. All known captures use 1 and receive uncompressed records.
  6. Whether a dive log read over BLE has the same 20-byte fingerprint available in any form inside the .DLF file.

References